Establishment of a Novel Method for Dose Distribution Verification in Stereotactic Radiosurgery (SRS) Using General Semiconductor Array Detectors.

Shunta Hirano, Takaaki Ito, Yuya Yanagi, Hiroyuki Kosaka, Kenji Matsumoto, Yukinori Matsuo, Hajime Monzen

Abstract read
In one paragraph

Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shunta HiranoDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, JPN.
Takaaki ItoDepartment of Radiological Technology, Kobe City Nishi-Kobe Medical Center, Kobe, JPN.
Yuya YanagiDepartment of Radiology, Shiga University of Medical Science, Otsu, JPN.
Hiroyuki KosakaDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, JPN.
Kenji MatsumotoDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, JPN.
Yukinori MatsuoDepartment of Radiation Oncology, Kindai University Faculty of Medicine, Osaka, JPN.
Hajime MonzenDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka, JPN.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stereotactic radiosurgery (SRS) involves steep dose gradients and small irradiation fields, which makes ensuring irradiation accuracy extremely important. While general semiconductor array detectors are reusable and cost-effective, their wide detector spacing results in insufficient spatial resolution. The aim of this study is to establish a novel patient-specific quality assurance (PSQA) method for single-isocenter multiple-target SRS volumetric modulated arc therapy (SIMT-SRS-VMAT) that can evaluate dose distribution with the same accuracy as radiochromic film by virtually narrowing the detector spacing by combining measurement with a general semiconductor array detector and translational movement of the treatment couch. Single-field plans with a single target and SIMT-SRS-VMAT plans with two targets were created for 1 cm lesions. Measurements using MapCHECK2 (Sun Nuclear, Melbourne, FL, USA) were combined with couch movement to synthesize measurement data at virtual detector spacings of 5, 4, 3, 2, and 1 mm. Root mean square error (RMSE) was used to evaluate profile shape accuracy, and γ analysis was used to evaluate dose distribution agreement. At virtual detector spacings of 10 mm, 5 mm, 4 mm, 3 mm, 2 mm, 1 mm, and with radiochromic film, the RMSE values in SIMT-SRS-VMAT were 8.02% ± 0.34%, 2.16% ± 0.07%, 1.60% ± 0.08%, 1.48% ± 0.17%, 1.32% ± 0.10%, 1.38% ± 0.03%, and 1.25% ± 0.02%, respectively. The RMSE decreased as the detector spacing narrowed, resulting in profile shapes comparable to those obtained with radiochromic film. In γ analysis, setting the virtual detector spacing to 5 mm enabled analysis covering the entire dose range, and the γ pass rate was comparable to EBT4 (Ashland Inc., Wayne, NJ, USA) for all tolerances. This study established a novel method of verification of dose distribution with the same accuracy as film, combining measurement with a general semiconductor array detector and translational movement of the treatment couch. With this approach, specialized high-resolution SRS array detectors and disposable radiochromic film are not needed, making SRS PSQA less costly and manpower-intensive.

Indexed as

dose distributionpatient-specific quality assurancesemiconductor dosimeterstereotactic radiation therapyvmat-srs