ReviewCureus2025

Comparative Accuracy of Electronic Apex Locators and Conventional Radiography for Working Length Determination in Permanent Teeth: A Systematic Review.

Naser A Alarifi, Abdulrahman M Alqahtani, Abrar Z Alharbi, Musaed H Alanazi, Abdulrahman M Alanazi, Ahmed F Alharbi, Naif F Alanazi, Khaled M Aloatibi, Fawaz S Alatallah, Haider A Alali and 1 more

Abstract readReview
In one paragraph

Review in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Naser A AlarifiDental Department, Albaha University, Albaha, SAU.
Abdulrahman M AlqahtaniGeneral Dentistry, Ministry of Health, Riyadh, SAU.
Abrar Z AlharbiGeneral Dentistry, Ministry of Health, Jeddah, SAU.
Musaed H AlanaziCollege of Dentistry, Majmaah University, Majmaah, SAU.
Abdulrahman M AlanaziCollege of Dentistry, Majmaah University, Majmaah, SAU.
Ahmed F AlharbiCollege of Dentistry, Majmaah University, Majmaah, SAU.
Naif F AlanaziCollege of Dentistry, Majmaah University, Majmaah, SAU.
Khaled M AloatibiCollege of Dentistry, Majmaah University, Majmaah, SAU.
Fawaz S AlatallahGeneral Dentistry, Ram Clinics, Dammam, SAU.
Haider A AlaliGeneral Dentistry, Ram Clinics, Dammam, SAU.
Abdulelah M KoabanDentistry, King Fahad Medical City, Riyadh, SAU.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate working length determination is essential for the success of root canal treatment. While radiographs have traditionally been used for this purpose, electronic apex locators (EALs) have been introduced as an alternative diagnostic tool. This systematic review and meta-analysis compared the accuracy of EALs with conventional and digital radiographs for working length determination in vivo and ex vivo studies. A comprehensive search of PubMed, Cochrane Library, LILACS, EBSCO, and Google Scholar was conducted, and 16 eligible studies were included. Across randomized controlled trials, EALs consistently achieved higher proportions of acceptable working length determinations, ranging from 87.0% to 92.1%, compared with 74.0% to 83.1% for radiographs, while the incidence of overextended cases was markedly lower in EAL groups. In vivo and ex vivo investigations confirmed that EALs provided superior or comparable accuracy to radiographs within the accepted tolerance range of ±0.5-1.0 mm of the apical constriction. Risk-of-bias assessment using QUADAS-2 indicated concerns in patient selection and reference standard domains, although the index test domain was generally low risk. Overall, the evidence suggests that EALs are more accurate and reliable than radiographs in determining working length, supporting their integration into endodontic practice, although further standardized, multicenter studies are needed to reinforce clinical recommendations.

Indexed as

electronic apex locator (eal)endodontic treatment outcomesradiographic accuracyroot canal measurementworking length determination

Identifiers

PMID41210007
PMCPMC12590451

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.