Evidence map›Paper›PMID 41209284›Full record

ArticleQuantitative imaging in medicine and surgery2025

Correlation between carotid Doppler ultrasound-derived parameters and cardiac output measurements: a systematic review and meta-analysis.

Feng Chen, Tao-Tao Peng, Hua-Wei Liu, Zhen-Xin Duan, Mi Yang, Hong Li

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Feng ChenDepartment of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.ORCID https://orcid.org/0000-0002-8894-4297
Tao-Tao PengDepartment of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.
Hua-Wei LiuDepartment of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.
Zhen-Xin DuanDepartment of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.
Mi YangDepartment of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.
Hong LiDepartment of Anesthesiology, The Second Affiliated Hospital of Army Medical University, Chongqing, China.ORCID https://orcid.org/0009-0009-0493-623X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The utility of carotid Doppler ultrasound (CDU) as a noninvasive tool for cardiac output (CO) monitoring has been a subject of considerable debate. This meta-analysis was conducted to synthesize the available evidence and quantitatively assess the correlation between CDU-derived parameters and standard CO measurements. Methods: We searched the databases of PubMed, EMBASE, Science Direct/Elsevier, MEDLINE, Web of Science, Cochrane Library, China National Knowledge Infrastructure, and China Biology Medicine from the date of inception up to August 2024. Data were analyzed by extracting Pearson's or Spearman's correlation coefficients from each study and converting them to Fisher's Z. The pooled r value was calculated using Fisher's Z and standard error. STATA (Version 15.0) software was used to facilitate data synthesis. Results: After screening titles and abstracts, 476 studies required full-text evaluation. Based on the inclusion and exclusion criteria, 17 observational studies were selected for meta-analysis. The results indicated a positive correlation between CDU-derived parameters and CO measurements [0.53, 95% confidence interval (CI): 0.39-0.64], with parameter change values being more relevant than absolute values (0.76, 95% CI: 0.49-0.90) versus (0.43, 95% CI: 0.27-0.57). Furthermore, the carotid velocity-time integral (CVTI) exhibited a stronger correlation (0.81, 95% CI: 0.62-0.91) than the other three parameters (carotid-corrected flow time 0.59, 95% CI: 0.31-0.77), carotid peak systolic velocity (0.40, 95% CI: 0.21-0.57), and carotid blood flow (0.33, 95% CI: 0.12-0.52) in the subgroup analysis. Egger regression analysis and the trim-and-fill method indicated no publication bias (P>0.05). Conclusions: CDU-derived parameters demonstrated positive correlations with CO measurements, providing evidence for the use of CDU-derived parameters as surrogate CO monitors.

Indexed as

cardiac output (CO)Carotid arteriescorrelationmeta-analysisultrasound

Identifiers

PMID41209284
PMCPMC12591915

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.