Evidence map›Paper›PMID 41207906›Full record

ArticleEcho research and practice2025

Discrepancies and potential impacts of self-reported versus measured height and weight on adult transthoracic echocardiography findings.

Christopher Benson, David Austin, Richard Graham, Chris Wilkinson

Abstract read
In one paragraph

Article in Echo research and practice, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christopher BensonAcademic Cardiovascular Unit, South Tees NHS Foundation Trust, Middlesbrough, UK. Christopher.benson4@nhs.net.
David AustinAcademic Cardiovascular Unit, South Tees NHS Foundation Trust, Middlesbrough, UK.
Richard GrahamAcademic Cardiovascular Unit, South Tees NHS Foundation Trust, Middlesbrough, UK.
Chris WilkinsonAcademic Cardiovascular Unit, South Tees NHS Foundation Trust, Middlesbrough, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAccurate chamber quantification in transthoracic echocardiography (TTE) is important for guiding clinical decision-making. We aimed to assess the accuracy and reliability of patients' self-reported height and weight compared to measured height and weight, and how any differences in the calculated body surface area (BSA) may affect TTE parameter classification.

methodsConsecutive patients attending for out-patient TTE were prospectively recruited at a large NHS Trust as part of a service evaluation. Height and weight were initially self-reported and then measured. TTE parameters were subsequently indexed to BSA or height based on both self-reported and measured values and compared.

results698 patients participated. Self-reported and measured height, weight, and BSA were strongly correlated (r > 0.90). There was a difference between the mean self-reported and measured height (self-reported being 1.1 cm higher, p < 0.001) and weight (self-reported being 1.6 kg lower, p < 0.001) as well as the resulting BSA (self-reported being 0.01m

conclusionCompared to measured height, weight and calculated BSA, self-reported values are statistically different but result in little clinically important change to TTE parameters in out-patients attending for TTE. However, given the possible impact on clinical decision-making, TTE conclusions based on self-reported height and weight should be interpreted with care, particularly indexed left ventricular volumes and aorta dimensions. Echocardiographers should be vigilant in identifying rare cases where individuals significantly misreport their height or weight.

Indexed as

Body surface areaEstimated heightEstimated weightSelf-reported heightSelf-reported weightService evaluationTransthoracic echocardiography

Identifiers

PMID41207906
PMCPMC12599019

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.