ArticleMedical physics2025

Sensitivity analysis of key CT simulation parameters and their impact on quality of virtual images.

Isabel Montero, Ehsan Samei, Ehsan Abadi

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Isabel MonteroCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University, Durham, North Carolina, USA.
Ehsan SameiCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University, Durham, North Carolina, USA.
Ehsan AbadiCenter for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University, Durham, North Carolina, USA.

Funding

TR&D Project 3: Virtual ReadersP41EB028744 · NIBIB · DUKE UNIVERSITY · PI Ehsan Samei · 2021 to 2026
$7.8M
Accuracy and Precision in CT Quantification of COPD Through Virtual Imaging TrialsR01HL155293 · NHLBI · DUKE UNIVERSITY · PI ABADI, EHSAN · 2021 to 2025
$2.2M
NHLBI NIH HHS R01 HL155293NIBIB NIH HHS P41 EB028744NIH HHS P41EB028744NIH HHS R01HL155293
6 · The paper itself

Abstract

backgroundTrials of medical imaging systems using clinical cases are often impractical motivating the use of virtual imaging trials (VITs). To emulate reality, VITs need models of imaging systems, whose realism depends on simulation parameter choice. PURPOSE: To evaluate how simulation parameter choice impacts image quality of virtual Computed Tomography (CT) images.

methodsUtilizing a validated CT simulator (DukeSim, Duke University), a size-variant and an anthropomorphic computational phantom were imaged emulating a clinical scanner (SOMATOM Force, Siemens Healthineers) and adult abdomen protocol. Simulations varied parameters associated with x-ray source, phantom, and detector: source and detector subsampling (1-5, each side), anode heel effect severity (0%-40%), x-ray spectrum shape (± 5 keV effective energy shift), phantom voxel size (0.1-0.5 mm), and detector crosstalk magnitude (0%-50%, per dimension). Simulations were reconstructed employing vendor-specific software (ReconCT, Siemens Healthineers). Sensitivity to parameter choice was assessed using modulation transfer function (MTF, spatial resolution), noise magnitude, noise power spectrum (NPS, noise texture), and mean CT number.

resultsMTF was sensitive to subsampling and crosstalk, with average changes in half-value frequency (f

conclusionSimulation parameter choice impacts virtual CT image quality. Certain parameters exert greater influence and may need extra attention when developing and utilizing VITs.

Indexed as

Computer SimulationDiagnostic ImagingImage Processing, Computer-AssistedTomography, X-Ray ComputedHumansPhantoms, ImagingCT SimulationQuantitative ImagingVirtual Clinical Trials

Identifiers

PMID41206354
PMCPMC13038297

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.