Evidence map›Paper›PMID 41206352›Full record

ArticleMedical physics2025

Multipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernels.

Aravind R Krishnan, Thomas Z Li, Lucas W Remedios, Michael E Kim, Chenyu Gao, Gaurav Rudravaram, Elyssa M McMaster, Adam M Saunders, Shunxing Bao, Kaiwen Xu and 5 more

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Aravind R KrishnanDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Thomas Z LiDepartment of Biomedical Engineering, Vanderbilt University, Nashville, USA.
Lucas W RemediosDepartment of Computer Science, Vanderbilt University, Nashville, USA.
Michael E KimDepartment of Computer Science, Vanderbilt University, Nashville, USA.
Chenyu GaoDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Gaurav RudravaramDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Elyssa M McMasterDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Adam M SaundersDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Shunxing BaoDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Kaiwen XuInsitro, South San Francisco, USA.
Lianrui ZuoDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Kim L SandlerDepartment of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, USA.
Fabien MaldonadoDepartment of Medicine, Vanderbilt University Medical Center, Nashville, USA.
Yuankai HuoDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.
Bennett A LandmanDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, USA.

Funding

Integrated Training in Engineering and DiabetesT32DK101003 · NIDDK · VANDERBILT UNIVERSITY · PI Jamey D. Young · 2014 to 2026
$3.9M
Integrating imaging and biopsy-derived molecular markers for the pre-surgical detection of indolent and aggressive early stage lung adenocarcinomaR01CA275015 · NCI · BOSTON UNIVERSITY MEDICAL CAMPUS · PI Marc Elliott Lenburg, Fabien Maldonado · 2023 to 2026
$2.6M
Clinical Translational Science Award (CTSA) Program 5UL1TR002243-03Martineau Innovation Fund grant through the Vanderbilt-Ingram Cancer Center Thoracic Working GroupNational Center for Advancing Translation Science Award (NCATS)National Science Foundation CAREER 1452485NCATS NIH HHS UL1TR000445-06NCI Early Detection Research Network 2U01CA152662NCI NIH HHS NCIU01CA196405NCI NIH HHS R01 CA253923-04NCI NIH HHS R01 CA 253923-04S1NCI NIH HHS R01 CA275015NCRR NIH HHS UL1RR024975-01NIDDK NIH HHS T32 DK101003Vanderbilt Institute for Clinical and Translational Research
6 · The paper itself

Abstract

backgroundReconstruction kernels in computed tomography (CT) introduce variability in spatial resolution and noise distribution, creating systematic differences in quantitative imaging measurements, that icl, emphysema characterization in lung imaging. While harmonization across images reconstructed using different kernels from the same manufacturer is feasible, this can be challenging in multi-centre or longitudinal studies where images are acquired using kernels from different manufacturers. This variability results in heterogeneous quantitative measurements that are difficult to compare. Therefore, it is necessary to standardize all images to a common reference kernel. PURPOSE: We explore training a harmonization model using paired reconstruction kernels (obtained from the same manufacturer for a given subject) and unpaired reconstruction kernels (obtained across different manufacturers for different subjects) in a low dose lung cancer screening cohort, validating our approach through quantitative CT measurements. Our overall goal is to use both sets of data to construct a shared latent space while recognizing the ability of different types of data to contribute through different classes of loss functions.

methodsWe develop a multipath cycleGAN that enables multi-domain kernel harmonization through a shared latent space, domain specific encoder-decoder architectures, and discriminators trained in an unsupervised manner using a mixture of paired and unpaired data. We train our model using 100 scans each from seven representative kernels (Siemens B50f, Siemens B30f, GE BONE, GE STANDARD, GE LUNG, Philips C, and Philips D) from the National Lung Screening Trial (NLST) dataset, enabling harmonization across 42 different kernel combinations. Using 240 withheld scans from each kernel, we evaluate our approach on paired kernels using percent emphysema. For unpaired kernels, we harmonize all scans to the style of a reference soft kernel (Siemens B30f) and evaluate our model using percent emphysema, followed by a general linear model analysis that investigates the impact of age, sex, smoking status, and kernel on emphysema. Additionally, we harmonize all soft kernels to a reference hard kernel (Siemens B50f), quantifying percent emphysema. We assess anatomical consistency in unpaired kernels harmonized to a reference soft kernel by comparing segmentations of lung vessels, muscle, and subcutaneous adipose tissue derived from TotalSegmentator between the non-harmonized and harmonized images. We compare the performance of our model to the standard cycleGAN and a switchable cycleGAN model.

resultsFor paired kernels, the proposed multipath approach reduced differences in percent emphysema as seen from the Bland Altman analysis (p < 0.05), achieving the best performance on one kernel pair over the standard cycleGAN and on two pairs over the switchable cycleGAN.For unpaired kernels where all source kernels were harmonized to a reference soft kernel, our method mitigated differences in three of six kernels, comparable to the switchable cycleGAN, while the standard cycleGAN mitigated differences in four of six kernels. When harmonizing all soft kernels to a reference hard kernel, our approach outperformed the switchable cycleGAN and was comparable to the standard cycleGAN. Our proposed approach maintains anatomical consistency in muscle, adipose tissue across all unpaired kernels and showed reasonable overlap on three kernels for lung vessels when compared to the cycleGAN; however, performance was lower when compared to the switchable cycleGAN.

conclusionsPaired and unpaired kernel harmonization with a shared latent space multipath cycleGAN mitigates errors in emphysema quantification and maintains anatomical consistency after harmonization.

Indexed as

Image Processing, Computer-AssistedLungRadiation DosageTomography, X-Ray ComputedHumansLung Neoplasmsmultipath cycleGANpercent emphysemareconstruction kernelshared latent space

Identifiers

PMID41206352
PMCPMC12596234

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.