Evidence map›Paper›PMID 41204323›Full record

ArticleBMC cardiovascular disorders2025

Detection of atrial fibrillation via artificial intelligence-assisted auscultation.

Yongzhe Guo, Huizhong Lin, Hui Chen, Xianhong Wu, Yukun Luo

Abstract readComparative StudyValidation Study
In one paragraph

Article in BMC cardiovascular disorders, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yongzhe Guo *Department of Cardiology, Fujian Institute of Coronary Heart Disease, Fujian Medical Center for Cardiovascular Diseases, Fujian Medical University Union Hospital, No. 29 Xinquan Road, Fuzhou, Fujian Province, China.
Huizhong Lin *Department of Cardiology, Fujian Institute of Coronary Heart Disease, Fujian Medical Center for Cardiovascular Diseases, Fujian Medical University Union Hospital, No. 29 Xinquan Road, Fuzhou, Fujian Province, China.
Hui ChenDepartment of Cardiology, Fujian Institute of Coronary Heart Disease, Fujian Medical Center for Cardiovascular Diseases, Fujian Medical University Union Hospital, No. 29 Xinquan Road, Fuzhou, Fujian Province, China.
Xianhong WuFujian Feizi Internet of Things Technology Co. LTD, Fuzhou, China.
Yukun LuoDepartment of Cardiology, Fujian Institute of Coronary Heart Disease, Fujian Medical Center for Cardiovascular Diseases, Fujian Medical University Union Hospital, No. 29 Xinquan Road, Fuzhou, Fujian Province, China. 569284142@qq.com.

Funding

Fujian Provincial Health Technology Project 2021QNA021Fujian Provincial Natural Science Foundation of China 2023J01632Joint Funds for the Innovation of Science and Technology, Fujian Province 2024Y9246
6 · The paper itself

Abstract

backgroundAtrial fibrillation (AF) is a prevalent arrhythmia with significant health risks, often underdiagnosed due to limitations in traditional screening methods. This study investigates the effectiveness of an AI-based electronic stethoscope for AF screening, comparing it to other portable devices.

methodsA retrospective study was conducted using 496 cardiac sound recordings from patients with and without AF. The recordings were divided into derivation and validation datasets. An AI model, combining ResNet34 and a 12-layer Vision Transformer (ViT), was developed and trained on the derivation dataset. The model's performance was evaluated using sensitivity, specificity, accuracy, positive and negative predictive values, and the area under the receiver operating characteristic (ROC) curve (AUC). Additionally, a non-consecutive day twice cardiac sound collection was performed on 74 samples to assess the model's consistency.

resultsThe AI model achieved high performance metrics in both derivation and validation datasets. In the derivation dataset, sensitivity was 0.95 (95% CI, 0.90-0.97), specificity was 0.90 (95% CI, 0.83-0.94), accuracy was 0.92 (95% CI, 0.90-0.96), positive predictive value was 0.92 (95% CI, 0.87-0.96), and negative predictive value was 0.93 (95% CI, 0.86-0.96). In the validation dataset, sensitivity was 0.94 (95% CI, 0.88-0.98), specificity was 0.91 (95% CI, 0.83-0.96), accuracy was 0.93 (95% CI, 0.89-0.96), positive predictive value was 0.93 (95% CI, 0.86-0.97), and negative predictive value was 0.93 (95% CI, 0.85-0.97). The AUC for the derivation dataset was 0.92 (95% CI, 0.89-0.96), and for the validation dataset, it was 0.93 (95% CI, 0.88-0.97). The non-consecutive day cardiac sound collection resulted in a Cohen's Kappa value of 0.74, indicating good consistency in the model's judgments.

conclusionThe AI-based electronic stethoscope shows promise as a reliable and accessible tool for AF screening, with potential applications in primary healthcare and general population screening.

Indexed as

Artificial IntelligenceAtrial FibrillationHeart AuscultationSignal Processing, Computer-AssistedStethoscopesAgedFemaleHumansMaleMiddle AgedPredictive Value of TestsReproducibility of ResultsRetrospective StudiesArtificial intelligence (AI).Atrial fibrillation (AF)Auscultation

Identifiers

PMID41204323
PMCPMC12595621

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.