ArticleMicrobial biotechnology2025
Highly Sensitive Field Detection Technology for Anthrax Based on the CRISPR/Cas13a System.
Article in Microbial biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Establishment of duplex multi-enzyme isothermal rapid amplification detection method for bovine astrovirus and norovirus.Frontiers in veterinary science · 2026Article
- Highly Sensitive Field Detection Technology for Anthrax Based on the CRISPR/Cas13a System.Microbial biotechnology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
In this study, we established a highly sensitive on-site detection technology for Bacillus anthracis. Firstly, we integrated Multiple Enzyme Isothermal Rapid Amplification (MIRA) with the clustered regularly interspaced short palindromic repeats (CRISPR) /associated protein 13a (CRISPR/Cas13a) detection system to develop a highly sensitive CRISPR/Cas13a assay. After testing crRNA selection, MIRA primers, reaction temperature, and CRISPR detection conditions, the CRISPR/Cas13a detection system employing dual crRNAs achieved a detection limit of 1000 copies/mL for B. anthracis. Quantitative analysis was additionally attempted. Compared with other common respiratory pathogens, the assay demonstrated high specificity. In clinically simulated samples, all 20 positive specimens were correctly identified, and all 13 negatives were unambiguously classified as negative. Based on these findings, we established a CRISPR point-of-care testing technology. By developing a CRISPR point-of-care testing device together with a tested lyophilised reagent system, the device achieved a detection limit of 250 copies/mL and delivered results within 30 min. All positive samples were accurately identified, and every negative sample was classified as negative. Consequently, this study presents a highly sensitive and portable technology for on-site detection of B. anthracis. It holds significant value for on-site detection of emerging infectious diseases.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.