Evidence map›Paper›PMID 41201953›Full record

ArticleMicrobial biotechnology2025

Highly Sensitive Field Detection Technology for Anthrax Based on the CRISPR/Cas13a System.

Jiao Fan, Luyao Huang, Jiahui Chen, Yaxuan Jiang, Xinying Du, Ligui Wang, Kanghui Ding, Jun Huang, Shaofu Qiu, Hongbo Liu and 1 more

Abstract readEvaluation Study
In one paragraph

Article in Microbial biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jiao FanChinese PLA Center for Disease Control and Prevention, Beijing, China.
Luyao HuangChinese PLA Center for Disease Control and Prevention, Beijing, China.
Jiahui ChenChinese PLA Center for Disease Control and Prevention, Beijing, China.
Yaxuan JiangChinese PLA Center for Disease Control and Prevention, Beijing, China.
Xinying DuChinese PLA Center for Disease Control and Prevention, Beijing, China.
Ligui WangChinese PLA Center for Disease Control and Prevention, Beijing, China.
Kanghui DingChinese PLA Center for Disease Control and Prevention, Beijing, China.
Jun HuangChinese PLA Center for Disease Control and Prevention, Beijing, China.
Shaofu QiuChinese PLA Center for Disease Control and Prevention, Beijing, China.ORCID 0000-0001-5070-9294
Hongbo LiuChinese PLA Center for Disease Control and Prevention, Beijing, China.ORCID 0000-0002-2320-3682
Hongbin SongChinese PLA Center for Disease Control and Prevention, Beijing, China.ORCID 0000-0002-2781-3031

Funding

National Science Foundation of China 32141003National Science Foundation of China 32300080
6 · The paper itself

Abstract

In this study, we established a highly sensitive on-site detection technology for Bacillus anthracis. Firstly, we integrated Multiple Enzyme Isothermal Rapid Amplification (MIRA) with the clustered regularly interspaced short palindromic repeats (CRISPR) /associated protein 13a (CRISPR/Cas13a) detection system to develop a highly sensitive CRISPR/Cas13a assay. After testing crRNA selection, MIRA primers, reaction temperature, and CRISPR detection conditions, the CRISPR/Cas13a detection system employing dual crRNAs achieved a detection limit of 1000 copies/mL for B. anthracis. Quantitative analysis was additionally attempted. Compared with other common respiratory pathogens, the assay demonstrated high specificity. In clinically simulated samples, all 20 positive specimens were correctly identified, and all 13 negatives were unambiguously classified as negative. Based on these findings, we established a CRISPR point-of-care testing technology. By developing a CRISPR point-of-care testing device together with a tested lyophilised reagent system, the device achieved a detection limit of 250 copies/mL and delivered results within 30 min. All positive samples were accurately identified, and every negative sample was classified as negative. Consequently, this study presents a highly sensitive and portable technology for on-site detection of B. anthracis. It holds significant value for on-site detection of emerging infectious diseases.

Indexed as

AnthraxBacillus anthracisCRISPR-Cas SystemsMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesHumansPoint-of-Care TestingSensitivity and SpecificityBacillus anthracisCRISPR/Cas13anucleic acid detectionpoint‐of‐care testing

Identifiers

PMID41201953
PMCPMC12594215

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.