ArticleMagnetic resonance in medicine2026
Brain Pulsation Imaging Using Non-Balanced Steady-State Free Precession With 3D-EPI Readout.
Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Quantification of cardiac-locked brainstem velocity at high resolution based on retrospectively-gated DENSE MRI at 7T.bioRxiv : the preprint server for biology · 2026Article
- Brain Pulsation Imaging Using Non-Balanced Steady-State Free Precession With 3D-EPI Readout.Magnetic resonance in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
purposeTo present a new, fast MR imaging method for visualization and quantification of pulsatile displacement in brain tissue and fluid.
methodsThe natural phase-contrast of non-balanced steady-state free precession combined with careful tuning of the intrinsic spoiler gradients is harnessed to measure displacement along specific physical directions. Efficient segmented 3D-EPI allows for whole brain coverage within TR = 0.15 s. Motion sensitive terms are added to the extended phase graph theory and simulations are used to optimize the sequence parameters and to calibrate the phase sensitivity. Pilot data on 4 healthy volunteers are acquired at 7T and analyzed after cardiac retrogating. A set of three 1-min scans with spoiler gradients along orthogonal axes is required to estimate full 3D displacement vectors.
resultsSimulations show that pulsatile displacements up to around 1 mm can be resolved with the proposed method. In vivo example data are in general agreement with predictions from simulations. The precision of the displacement measurements is estimated to be 0.01 mm using repeated scans of the same subject, and while estimated displacement values agree well with literature values for example tissue ROIs, the measurement accuracy needs to be further explored. The method provides a detailed view of the pulsatile motion along all three physical axes and with full 3D coverage of the brain.
conclusionBrain Pulsation Imaging allows for quantitative measurements of displacement vectors through the cardiac cycle with whole brain coverage within 3-5 min. The method is robust and should have significant potential for clinical application.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.