Biomechanical Evaluation of a Novel Bionic Hip Prosthesis Designed for Optimized Load Transfer and Initial Stability.

Zhentao Ding, Lijia Zhang, Xingguo Wu, Xiaomeng Zhang, Chen Xiong, Yanhua Wang, Dianying Zhang

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhentao DingDepartment of Orthopaedics and Trauma, Peking University People's Hospital, Beijing, China.
Lijia ZhangDepartment of Orthopaedics, Peking Union Medical College Hospital, Beijing, China.
Xingguo WuDepartment of Orthopaedics, Tianjin Fifth Central Hospital, Tianjin, China.
Xiaomeng ZhangDepartment of Orthopaedics and Trauma, Peking University People's Hospital, Beijing, China.ORCID https://orcid.org/0000-0002-1921-2914
Chen XiongDepartment of Orthopaedics and Trauma, Peking University People's Hospital, Beijing, China.ORCID https://orcid.org/0000-0001-9435-2661
Yanhua WangDepartment of Orthopaedics and Trauma, Peking University People's Hospital, Beijing, China.
Dianying ZhangDepartment of Orthopaedics and Trauma, Peking University People's Hospital, Beijing, China.ORCID https://orcid.org/0000-0001-8396-702X

Funding

Peking University People's Hospital PTU2021-06Peking University People's Hospital RZ2023-03
6 · The paper itself

Abstract

objectiveIn total hip arthroplasty, the femoral component design requires a trade-off between initial stability and stress shielding. We designed the new bionic hip arthroplasty (BHA) prosthesis with compression and tension screws to mimic compression and tension trabeculae for bionic reconstruction. This prosthesis is designed to reduce stress shielding by mimicking physiological load transfer while ensuring sufficient initial stability for successful bone integration. This study aimed to biomechanically evaluate the initial stability and migration pattern of the BHA prosthesis under dynamic and static loading conditions.

methodsThe BHA prostheses were implanted into ten Sawbones fourth-generation composite non-osteoporotic femurs. In dynamic fatigue testing, the irreversible displacements and migration patterns in vertical and rotational directions were analyzed after 1,000,000 loading cycles. In static failure testing, the failure load of the BHA implanted model was analyzed.

resultsIn dynamic fatigue testing, the irreversible subsidence displacement of the BHA prosthesis was (0.3683 ± 0.1046) mm and the irreversible retroversion displacement was (0.0328 ± 0.0157)°. The irreversible displacements in both vertical and rotational directions stabilized at 100,000 loading cycles. In static failure testing, the failure load of the BHA implanted model was (4485 ± 702) N.

conclusionsThe irreversible subsidence displacement of the BHA prosthesis was below the interface failure threshold of 1.5 mm, and secondary fixation was accomplished at 100,000 loading cycles. The average failure load was approximately 6.4 times body weight, much higher than the daily load range of hip joints. The BHA prosthesis suggests potential for adequate axial initial stability to facilitate bone ingrowth, which is expected to reduce revision rates in patients.

Indexed as

Arthroplasty, Replacement, HipBionicsHip ProsthesisProsthesis DesignBiomechanical PhenomenaHumansMaterials TestingProsthesis FailureWeight-Bearingbiomechanical testingbionic reconstructioninitial stabilitystress shieldingtotal hip arthroplasty

Identifiers

PMID41194745
PMCPMC12685485

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.