ArticleJournal of applied clinical medical physics2025

Analysis of the application of 3D-printed personalized positioning fixation in nasopharyngeal carcinoma radiotherapy.

Zeyu Ding, Guo-Quan Li, Qi Liu, Xiaohui Zhu, Lin Tan, Jun Kang, Ye Wang, Zhiyong Yang, Jinghua Ren, Jun Han and 1 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Zeyu DingSchool of Nuclear Science and Technology, University of South China, Hengyang, Hunan Province, China.
Guo-Quan LiCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Qi LiuCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.ORCID https://orcid.org/0000-0002-1881-1595
Xiaohui ZhuCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Lin TanSichuan Provincial People's Hospital, Chengdu, Sichuan Province, China.
Jun KangSchool of Nuclear Science and Technology, University of South China, Hengyang, Hunan Province, China.
Ye WangCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Zhiyong YangCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Jinghua RenCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Jun HanCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei Province, China.
Pinjing ChengSchool of Nuclear Science and Technology, University of South China, Hengyang, Hunan Province, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aims to evaluate the impact of personalized 3D-printed headrest devices on setup errors and dosimetry in nasopharyngeal carcinoma radiotherapy.

methodsA total of 50 nasopharyngeal carcinoma patients (28 male, 22 female, aged 24-76 years, mean age 45 years) who received radiotherapy at our center between July 1, 2023, and August 10, 2024, were randomly divided into two groups. Group A: 3D-printed headrest and thermoplastic mask (Klarity Medical); Group B: Standard headrest and thermoplastic mask. All patients underwent a simulation CT (Philips IntelliSpace; 120 kV/200 mAs, 3 mm slices) in a supine position. The VMAT plan (70 Gy/33 fx) was designed in Eclipse 15.6: Plan-P: Actual PLA CT values included; Plan-0: PLA CT values set to -1000 (control). Daily CBCT verification (Varian Halcyon) was performed to measure setup errors at the Clivus, C4, and C7 vertebral levels. The Van Herk formula was used to determine the appropriate planning target volume (PTV) margin. Dose measurements used PCI, HI, CR, Dmean, and Dmax to assess PTVs (GTVnx+nd, PTV1, PTV2) and OARs (brainstem, spinal cord, lens, optic nerve).

resultsA total of 340 CBCT images were collected from 50 patients, with 164 images from Group A and 176 from Group B. Setup errors in Group B were generally larger than those in Group A. Statistically significant differences were observed in the AP direction at the Clivus, C4, and C7 vertebral ROI registrations. Roll rotational errors showed statistically significant differences in ROI registration at C4 and C7 vertebral levels. The external radiation margins in all directions for Group A were smaller than those for Group B, with the largest difference observed at the C7 vertebral level. The external margins for the C7 ROI registration in the LR, SI, and AP directions were 2.91, 2.97, and 3.01 mm, respectively. Compared with Plan-0, the Dmean and CR of the target volumes PTVnd+nx and PTV1 showed statistically significant differences (p < 0.05). Differences in Dmean, CR, and PCI for PTV2 were also statistically significant (p < 0.05). For the dosimetric evaluation of critical organs adjacent to the target volume, statistically significant differences were observed in the maximum doses to the brainstem, spinal cord, left lens, left optic nerve, and right optic nerve between the two planning approaches (p < 0.05). However, no statistically significant differences were found in the mean doses to these organs at risk (OARs) (p > 0.05).

conclusionThe application of 3D-printed immobilization technology significantly improves setup accuracy in nasopharyngeal carcinoma radiotherapy and reduces cervical spine displacement. The incorporation of 3D-printed materials exerts a measurable influence on target volume dose distribution and may notably increase the maximum dose delivered to adjacent critical organs.

Indexed as

Nasopharyngeal CarcinomaNasopharyngeal NeoplasmsPatient PositioningPrinting, Three-DimensionalRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRadiotherapy Setup ErrorsAdultAgedFemaleHumansMaleMiddle AgedOrgans at RiskRadiotherapy DosageYoung Adult3D printingcone‐beam CT (CBCT)dose distributionnasopharyngeal carcinomapersonalized immobilizationplanning target volume (PTV)setup accuracy