ArticleMagnetic resonance in medicine2026
Wireless Resonators With Coupled Versus Decoupled Units: Which Enhances Local SNR of RF Receive Arrays Better?
Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Low-Cost and Detunable Wireless Resonator Glasses for Enhanced Eye MRI With Concurrent High-Quality Whole-Brain MRI.Magnetic resonance in medicine · 2026Article
- Wireless Resonators With Coupled Versus Decoupled Units: Which Enhances Local SNR of RF Receive Arrays Better?Magnetic resonance in medicine · 2026Article
- Reducing RF-Induced Heating of DBS in 3 T MRI Using Dual-Role Receive Arrays as Wireless Resonators: A Simulation Study.IEEE access : practical innovations, open solutions · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo compare two identically sized wireless resonator designs, one with strongly coupled units and the other with decoupled units, for their ability to enhance receive performance in MRI when used with local receive arrays.
methodsBoth wireless resonator designs were fabricated and experimentally evaluated for detuning efficiency, SNR improvements, and parallel imaging performance (g-factor) at 1.5 T. They were used alongside a 12-channel head receive array, with the standard body coil serving as the RF transmitter.
resultsExperimental data showed that the wireless resonator with decoupled units consistently outperformed that with coupled units, with up to threefold improvement in SNR and a reduction of maximum/average g-factor from 4.6/1.8 to 3.1/1.3. Notably, compared to the original receive array (maximum/average: 3.9/1.7), the decoupled design further improved the g-factor, highlighting superior performance in accelerated imaging.
conclusionWireless resonators with decoupled units offer significant advantages in improving MRI image quality and parallel imaging performance over their coupled counterparts. Their ease of detuning and pronounced gains in SNR and g-factor make them a compelling choice for wireless resonator designs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials