Evidence map›Paper›PMID 41188502›Full record

ArticleScientific reports2025

Portable mixed reality navigation system for neurosurgery: a clinical feasibility study.

Zhongjie Shi, Yilong Peng, Xin Gao, Xiaojun Li, Gang Chen, Shujie Sun, Zhanxiang Wang

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhongjie ShiDepartment of Neurosurgery, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361003, China.
Yilong PengDepartment of Neurosurgery, Jiangmen Central Hospital, Jiangmen, 529001, China.
Xin GaoDepartment of Neurosurgery, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361003, China.
Xiaojun LiDepartment of Neurosurgery, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361003, China.
Gang ChenDepartment of Neurosurgery, Zhuhai People's Hospital, Zhuhai, 519001, China. jhy_edu@163.com.
Shujie SunDepartment of Neurosurgery, Xuhui District Central Hospital, Shanghai, 200041, China.
Zhanxiang WangDepartment of Neurosurgery, The First Affiliated Hospital of Xiamen University, School of Medicine, Xiamen University, Xiamen, 361003, China. wzxcn@foxmail.com.

Funding

Jiangmen Key Project of Basic and Applied Basic Research 2021030103490007335National Natural Science Foundation of Fujian Province 2022J011355
6 · The paper itself

Abstract

This study aimed to develop a portable mixed reality navigation (PMRN) system for neurosurgery and assess its feasibility, providing design insights for the optimization and wider adoption of mixed reality navigation. The PMRN system linked a head-mounted display (HMD) and a portable laptop via a router, forming a local network. Active infrared tracking enabled real-time localization of a custom surgical probe. Accuracy was first tested in a laboratory using simulation models, then evaluated in a prospective clinical study of 42 patients with intracranial lesions. Clinically, the probe of a traditional optical navigation (TON) system was placed at PMRN-localized targets, and the Euclidean distance between the two systems was measured to quantify localization error. Doctors also subjectively assessed the alignment of mixed reality holograms with patient anatomy to evaluate reliability. In laboratory testing, two doctors each performed 10 simulated head model localizations, with an average time of under 5 min. The times decreased with practice and stabilized at approximately 3.5 min. The maximum fiducial registration error (FRE) and target registration error (TRE) were 2.5 mm and 2.3 mm, respectively, with no significant difference between doctors. In the clinical study (n = 42 patients), the mean localization time was 4.3 ± 1.0 min, the FRE was 2.2 ± 0.7 mm, and the TRE was 1.7 ± 0.5 mm. Doctors rated the hologram-patient alignment as satisfactory in 40 cases (95%); the remaining two cases showed a 3 mm deviation, which was attributed to slight patient movement or reduced device performance in low-battery mode. The PMRN system is portable, easy to use, and achieves millimeter-level accuracy in neurosurgical procedures with high surgeon satisfaction. It meets the needs of most routine operations but requires further refinement for submillimeter-precision procedures. These results confirm its clinical feasibility and support its further development and adoption in mixed reality neurosurgical navigation.

Indexed as

NeuronavigationNeurosurgical ProceduresSurgery, Computer-AssistedAdultAgedAugmented RealityFeasibility StudiesFemaleHumansMaleMiddle AgedProspective StudiesClinical feasibility studyHead-mounted displayMixed reality navigationNeurosurgery

Identifiers

PMID41188502
PMCPMC12586536

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.