Evidence map›Paper›PMID 41188477›Full record

ArticleScientific reports2025

Vibration, temperature, and humidity influence the perception of electrocutaneous stimulation for occupational warning.

Eva-Maria Dölker, Daniel Gröllich, Martin Schmauder, Jens Haueisen

Abstract readMulticenter Study
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Eva-Maria Dölker *Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693, Ilmenau, Germany. eva-maria.doelker@tu-ilmenau.de.
Daniel Gröllich *Institute of Material Handling and Industrial Engineering, Chair of Ergonomics, Technische Universität Dresden, 01307, Dresden, Germany.
Martin SchmauderInstitute of Material Handling and Industrial Engineering, Chair of Ergonomics, Technische Universität Dresden, 01307, Dresden, Germany.
Jens HaueisenInstitute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693, Ilmenau, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electrocutaneous stimulation can be used to warn workers in hazardous situations. To determine parameters for the operating ranges of such warning systems we investigated the influences of vibrations, temperature, and humidity on the perception, attention, muscle twitch, and intolerance thresholds of healthy volunteers in a multi-center study. In a study on 94 participants, vibrations with amplitudes of 2 mm, 5 mm, and 8 mm and at frequencies of 8 Hz and 9.5 Hz were applied to the right arm. In a second study, 52 participants experienced temperature and humidity variations within a climate chamber in four conditions: dry cold (13.8 ± 1.6 [Formula: see text]C, 33.9 ± 9.2% relative humidity (RH)), dry warm (41.3 ± 1.7 [Formula: see text]C, 24.6 ± 5.8% RH), wet cold (12.0 ± 1.6 [Formula: see text]C, 88.5 ± 8.2% RH), and wet warm (41.3 ± 2.1 [Formula: see text]C, 65.5 ± 9.0% RH). In both studies, the upper right arm was electrically stimulated with electrodes of size 25 mm×40 mm, and thresholds were determined. Perception, attention, and intolerance thresholds increased with vibration amplitude and frequency from median values of 5 mA, 9.9 mA and 19.3 mA for perception, attention and intolerance thresholds during rest to 14.6 mA, 20 mA and 21 mA during vibration amplitude of 8 mm and frequency of 9.5 Hz. Perception thresholds slightly increased with decreasing temperature with median values of 4.1 mA during dry cold vs. 3.8 mA during dry warm condition and 4.0 mA during wet cold vs. 3.8 mA during wet warm condition for an electrode pair at a lateral position. Muscle twitch thresholds slightly increased with increasing temperature at the lateral electrode pair with median values of 17.4 mA during dry cold vs. 18.8 mA during dry warm condition and 17.5 mA during wet cold vs. 18.7 mA during wet warm condition. For both studies, women showed smaller perception and attention thresholds. For illustration, in study 1, the median values of the perception threshold during rest were 4.1 mA for women and 5.7 mA for men, whereas the median values for the attention threshold were 9.1 mA for women and 11.4 mA for men, respectively. Additionally, women experienced less muscle twitching. To exemplify this, 50% of the women experienced muscle twitches compared to 66% of the men at a lateral electrode pair in study 2. We conclude that the operating range of future electrical warning systems needs to be flexibly adjusted to the working conditions. The influence of the climate conditions was minor, suggesting that electrocutaneous warning systems can operate robustly across diverse environments. This supports their practical applicability and motivates future research on optimized dry or textile-based electrodes to enhance usability in real-world settings.

Indexed as

HumidityOccupational ExposurePerceptionTemperatureTranscutaneous Electric Nerve StimulationVibrationAdultFemaleHealthy VolunteersHumansMaleMiddle AgedSensory ThresholdsYoung Adult

Identifiers

PMID41188477
PMCPMC12586676

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.