Evidence map›Paper›PMID 41188215›Full record

ArticleMicrosystems & nanoengineering2025

Monolithically integrated triaxial high-performance high-g accelerometer for high shock vibration signal measurements.

Mingzhi Yu, Xiaoyu Wu, Libo Zhao, Chen Jia, Yong Xia, Xiangguang Han, Tao Wang, Guoxi Luo

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Mingzhi YuState Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi'an Jiaotong University, Xi'an, 710049, China.ORCID http://orcid.org/0000-0003-4706-0863
Xiaoyu WuSchool of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China. XYmems@stu.xjtu.edu.cn.
Libo ZhaoState Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi'an Jiaotong University, Xi'an, 710049, China. libozhao@xjtu.edu.cn.ORCID http://orcid.org/0000-0001-6101-8173
Chen JiaState Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi'an Jiaotong University, Xi'an, 710049, China. chenjia@xjtu.edu.cn.
Yong XiaState Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi'an Jiaotong University, Xi'an, 710049, China.
Xiangguang HanState Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi'an Jiaotong University, Xi'an, 710049, China.
Tao WangSchool of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
Guoxi LuoState Key Laboratory for Manufacturing Systems Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Xi'an Jiaotong University, Xi'an, 710049, China.

Funding

National Natural Science Foundation of China (National Science Foundation of China) 52305615
6 · The paper itself

Abstract

High-g accelerometers serve as critical components in real-time monitoring systems for shock vibration analysis of blast fuzes in both penetrating and hypersonic weapon applications. While piezoresistive accelerometers can theoretically achieve both high sensitivity and broad frequency response when the piezoresistive beam (piezoresistor) undergoes pure axial deformation, previous approaches required intricate theoretical calculations and specific structural configurations to approximate pure axial deformation conditions, substantially complicating the design process. This study presents an innovative triaxial high-g piezoresistive accelerometer design featuring position-independent pure axial deformation of the piezoresistive beam, capable of measuring accelerations up to 200,000 g. The key innovation lies in the synchronized deformation mechanism at both ends of the piezoresistive beam, which effectively cancels out transverse deformation components. This novel approach eliminates the need for complex design procedures while ensuring pure axial deformation throughout the measurement range. Experimental validation demonstrates exceptional performance characteristics: an ultra-high natural frequency exceeding 1.5 MHz coupled with high sensitivity greater than 1.15 μV/g at 5 V excitation, which provides a convenient method for the design of high-performance piezoresistive accelerometers.

Identifiers

PMID41188215
PMCPMC12586674

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.