Evidence map›Paper›PMID 41186812›Full record

ArticleAnnals of biomedical engineering2026

Automatic Image Co-registration of Carotid Angiography and Intravascular Optical Coherence Tomography Based on Machine Learning Method: A Pilot Feasibility Study.

Hui Xu, Jia-Nan Li, Yan Xu, Jun-Ren Ma, Kang Zong, Rui Zhu, Yi-Hui Cao, Peng-Fei Yang, Rui Zhao, Jian-Min Liu

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hui Xu *Neurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China.
Jia-Nan Li *Shenzhen Vivolight Medical Device & Technology CO., Shanghai, China.
Yan XuSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
Jun-Ren MaNeurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China.
Kang ZongNeurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China.
Rui ZhuShenzhen Vivolight Medical Device & Technology CO., Shanghai, China.
Yi-Hui CaoShenzhen Vivolight Medical Device & Technology CO., Shanghai, China.
Peng-Fei YangNeurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China. p.yang@vip.163.com.
Rui ZhaoNeurovascular Center, Changhai Hospital, Naval Medical University, Yangpu No.168, Changhai Road, Shanghai, China. z_ray1979@126.com.
Jian-Min LiuOriental Pan-Vascular Devices Innovation College, University of Shanghai for Science and Technology, Shanghai, China.

Funding

National Natural Science Foundation of China 81671137National Natural Science Foundation of China 82001262National Natural Science Foundation of China 82371316Shenzhen Research Foundation KJZD20240903103304006
6 · The paper itself

Abstract

purposeThis study proposes a novel algorithm framework for optical coherence tomography (OCT) and carotid angiography co-registration (cACR), aiming to improve diagnostic precision and treatment planning for carotid artery disease.

methodsThe OCT-cACR algorithm integrates an enhanced U-Net segmentation model and a marker detection algorithm for segmenting target carotid vessels and detecting OCT probe markers. Based on the segmented target region, the You Only Look Once (YOLO) algorithm is further utilized to detect and track the OCT probe marker. The acquisition time point of each frame served as the matching parameter to achieve registration between the two modalities. Following registration, an expert compared the identified marker position on each angiography frame with its corresponding actual location to measure the resulting geographical error. The accuracy of cACR was validated using four real clinical cases, with a geographical error of less than 0.35 mm as the evaluation criterion.

resultsThe segmentation model achieved higher accuracy (Dice coefficient: 0.867 ± 0.166) compared to baseline U-Net models. OCT-cACR demonstrated an accuracy of 93.33 to 100% in four test cases, thus achieving precise alignment of angiography and OCT images.

conclusionThe proposed cACR approach is feasible and accurate and may serve as a promising tool for improving the diagnosis and treatment of carotid artery diseases.

Indexed as

AngiographyCarotid ArteriesCarotid Artery DiseasesImage Processing, Computer-AssistedMachine LearningTomography, Optical CoherenceAlgorithmsFeasibility StudiesHumansMalePilot ProjectsAngiography co-registrationArtificial intelligenceCarotid artery diseaseInterventional treatmentOptical coherence tomography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.