ArticleBone & joint research2025

Biomechanical comparison between custom-made enhanced triflange and quadri-flange acetabular components for the treatment of Paprosky IIIB acetabular bone defects.

Zhenqian Li, Aobo Zhang, Yang Liu, Hao Chen, Yifu Sun, Xue Zhao, Qing Han, Jincheng Wang

Abstract read
In one paragraph

Article in Bone & joint research, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zhenqian LiDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Aobo ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Yang LiuDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Hao ChenDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Yifu SunDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Xue ZhaoDepartment of Endocrinology and Metabolism, The First Hospital of Jilin University, Changchun, China.
Qing HanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Jincheng WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: The management of Paprosky IIIB acetabular bone defect is challenging in revision total hip arthroplasty. Custom-made acetabular components (CMAC) have been increasingly used in recent years. However, the iliac fixed flange of CMAC is still a mechanically weak area, where nonuniform stress distribution and micromotion may cause prosthesis failure. This study aimed to enhance the iliac fixation effect by enhancing the structure of the iliac flange or using a quadri-flange CMAC. The biomechanical performance was compared to provide a theoretical basis for clinical application. Methods: The inhomogeneous finite element analysis (FEA) model was reconstructed according to the Paprosky IIIB acetabular defect. The biomechanical performance of enhanced triflanged and quadri-flange CMAC was evaluated according to the peak stress and the Von Mises stress distribution under routine conditions. The relative micromotion between the pelvis and prosthesis was analyzed to assess the stability of the implant. Results: The peak stresses of the enhanced triflanged and quadri-flange CMAC were 126.90 and 140.70 MPa under gait cycle, respectively. The stress distribution in the enhanced triflanged CMAC was more uniform. In contrast, nonuniform stress distribution and larger high-stress concentration regions were found in the quadri-flange CMAC, especially in the screw contact sites between the screw and superolateral bone of the ilium. The results of micromotion showed that there was a larger proportion of units with > 28 μm in the quadri-flange CMAC (15%), while the enhanced triflanged CMAC structure had a smaller ratio (8%). Conclusion: The enhanced triflanged CMAC has better stress, stress distribution, and micromotion than quadri-flange CMAC in this model. In cases where both prostheses are suitable for use, the enhanced triflanged CMAC is more highly recommended.