Evidence map›Paper›PMID 41185070›Full record

ArticleJournal of health, population, and nutrition2025

Impact of volume-based procurement policy on coronary stent use in tianjin: interrupted time series analysis.

Zhao Yang, Liangyu Ni, Wei Zhao, Yuxi Li, Yongyi Wu, Qiyun Zhu, Linlin Da, Weijia Liu, Qi Zhang, Jianping Li and 1 more

Abstract read
In one paragraph

Article in Journal of health, population, and nutrition, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Zhao Yang *Peking University First Hospital, Beijing, 100034, China.
Liangyu Ni *Peking University School of Basic Medicine, Beijing, China.
Wei Zhao *Department of Endocrinology and Metabolism, Peking University Peoples Hospital, Beijing, China.
Yuxi Li *Peking University First Hospital, Beijing, 100034, China.
Yongyi WuSchool of Public Health, Kunming Medical University, Kunming, China.
Qiyun ZhuUniversity of California San Diego, Revelle College, La Jolla, CA, USA.
Linlin DaDepartment of Health Policy and ManagementRollins School of Public Health, Emory University, Atlanta, GA, USA.
Weijia LiuSchool of Pharmaceutical Sciences, Peking University, Beijing, China.
Qi ZhangSchool of Community and Environmental Health, College of Health Sciences, Old Dominion University, 3118 Health Sciences Building, Norfolk, VA 23529, USA.
Jianping LiPeking University First Hospital, Beijing, 100034, China. lijianping03455@pkufh.com.
Bin JiangResearch Centerof Public Policy, Peking University, Beijing, China. binjiang@bjmu.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study aimed to analyze the impact of China's centralized volume-based procurement policy on the procurement and utilization of coronary stents in Tianjin from 2019 to 2021.

methodsAn interrupted time-series design was used to assess monthly procurement data of coronary stents and balloons in Tianjin from January 2019 to December 2021.

resultsThe volume-based procurement policy significantly reduced coronary stents prices, with an average price reduction of 92.67% for ten selected stents, and the lowest price dropped to 469 CNY. Following policy implementation, annual procurement in Tianjin increased by 59.55%, and tertiary hospitals demonstrated a significant monthly level increase of 1,473.53 units (p = 0.027; 95% CI: 181.69-2,765.36). Imported stents procurement showed a significant level increase of 703.85 units (p < 0.0001), while domestic stents exhibited no significant monthly variation (p = 0.154). Structural upgrades accelerated: stainless steel stents decreased by 30.94% in usage share (p < 0.001; 95% CI: 17.36-44.52) and were rapidly phased out post-policy, whereas permanent-coated stents increased by 23.00% (p < 0.001; 95% CI: 18.46-27.54). Procurement expenditure decreased by 73.03% compared to the 2019 baseline. Drug-eluting balloons as an alternative technology remained unaffected (p = 0.32).

conclusionThe study shows that Tianjin's centralized volume-based procurement policy for coronary stents significantly improved stent supply and clinical utilization quality, while substantially reducing medical insurance expenditures-indicating that such policies can optimize healthcare resource allocation and enhance the cost-effectiveness of medical device procurement.

Indexed as

Health PolicyStentsChinaHumansInterrupted Time Series AnalysisChinaCoronary heart disease (CHD)Coronary stentVolume-based procurement

Identifiers

PMID41185070
PMCPMC12581602

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.