Evidence map›Paper›PMID 41180324›Full record

ArticleThe journal of advanced prosthodontics2025

Comparing impression techniques in the prosthodontic treatment for edentulous patients: a 3D finite element analysis.

Mary Delia Zoleta Bondoc, Mi-El Kim, Young-Jun Lim, Myung-Joo Kim, Ho-Beom Kwon

Abstract read
In one paragraph

Article in The journal of advanced prosthodontics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mary Delia Zoleta BondocDental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-4585-6972
Mi-El KimDental Research Institute and Department of Oral Anatomy, School of Dentistry, Seoul National University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0002-3280-6821
Young-Jun LimDental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-2504-9671
Myung-Joo KimDental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-2020-5284
Ho-Beom KwonDental Research Institute and Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea.ORCID https://orcid.org/0000-0003-4973-7727

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe biomechanical advantage of selective pressure impressions over mucocompressive techniques remains unclear. This study aimed to determine whether selective pressure techniques offer substantial biomechanical advantage over mucocompressive impressions using clinical computer simulation. MATERIALS AND

methodsTwo models were analyzed: Model C, with mucocompressive impression tray, and Model S, with selective pressure impression tray with 10-mm diameter circular relief in the midline. Each model included the tray, polyvinyl siloxane (PVS), mucosa, cortical, and cancellous bone. Seven locations were designated, from which the results were analyzed. With a vertical load of 49 N on the palatal area, pressure, von Mises stress, and displacement were evaluated. Statistical analysis was performed using paired-samples t-test and effect size estimation (Cohen's d).

resultsBoth models generated mucosal displacement and stress transmission to the underlying structures upon load application. In Location 3, where the relief was placed, Model S exhibited lower pressure, stress, and displacement than Model C, indicating localized force reduction. Conversely, other locations exhibited higher values in Model S than in Model C. Low stress in bone for both trays suggested that tray design had minimal effect on bone. All variations demonstrated small effect sizes (d ≤ 0.2), despite statistical significance (

conclusionSelective pressure trays modified tissue loading locally at the relief site; however, these did not seem to provide a substantial biomechanical advantage, particularly on bone. Their clinical relevance remains limited and needs further supporting evidence.

Indexed as

BiomechanicsDental impression techniqueEdentulous mouthFinite element analysisProsthodontics

Identifiers

PMID41180324
PMCPMC12575063

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.