ArticleFrontiers in oncology2025

BI-RADS application for breast cancer screening in primary healthcare settings: assessing protocol adherence and diagnostic validity.

Xiang Li, Hong Wang, Hui-Fang Xu, Shao-Kai Zhang, Bing-Jie Zheng, Hai-Liang Li

Abstract read
In one paragraph

Article in Frontiers in oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiang LiDepartment of Radiology, Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, China.
Hong WangDepartment of Cancer Epidemiology, Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, China.
Hui-Fang XuDepartment of Cancer Epidemiology, Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, China.
Shao-Kai ZhangDepartment of Cancer Epidemiology, Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, China.
Bing-Jie ZhengDepartment of Radiology, Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, China.
Hai-Liang LiDepartment of Radiology, Affiliated Cancer Hospital of Zhengzhou University & Henan Cancer Hospital, Zhengzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The application performance of the Breast Imaging-Reporting and Data System (BI-RADS) in primary healthcare settings remains uncertain. The normativity of BI-RADS classification and the efficacy of breast cancer detection guided by BI-RADS classification were evaluated here. Methods: All data used in the current study were derived from a breast cancer screening cohort baseline database, which consists of 8,996 women aged 35-64 years from Central China. Participants aged 35-44 underwent automated breast ultrasound (ABUS) and handheld ultrasound (HHUS), while those aged 45-64 were screened with ABUS, HHUS, and mammography (MG). All imaging diagnoses were made by radiologists according to the BI-RADS 5 Results: Of individuals found with irregular morphology, 44%, 45.7% and 77.4% were classified as BI-RADS category 4 or higher for HHUS, ABUS and MG, respectively; For those with indistinct margins, the proportion was 81%, 77.5% and 40.8%, correspondingly; For grouped calcifications, they were 100% for HHUS and 85.7% for MG; Meanwhile, 72.7% and 88.9% not parallel (taller than wide) masses were categorized as BI-RADS category 4 for HHUS and ABUS. The concordance of BI-RADS classification was as high as 98.2% between HHUS and ABUS (Kappa = 0.726), whereas it was about 96% between ultrasound and MG (Kappa ranged from 0.21 to 0.25). The BI-RADS guided screening performance for breast cancer showed AUC values of 0.9935 for ABUS, 0.9529 for HHUS, 0.8983 for MG. If the BI-RADS diagnosis of MG was considered in ultrasound-negative women, only the HHUS's performance was boosted, achieving an AUC of 0.9920. Conclusions: Radiologists at primary hospitals can effectively apply BI-RADS based on the malignant features they found. BI-RADS can provide a reliable framework for guiding breast cancer screening in primary healthcare settings.

Indexed as

automated breast ultrasoundBI-RADSbreast cancer screeninghandheld ultrasoundmammographyprimary healthcare setting

Identifiers

PMID41179676
PMCPMC12571612

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.