ArticleCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2026
Guidewire Manipulation Based on Establishment of Stereo Perception in Percutaneous Coronary Intervention.
Article in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Guidewire Manipulation Based on Establishment of Stereo Perception in Percutaneous Coronary Intervention.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
backgroundTraditional percutaneous coronary intervention (PCI) relies on two-dimensional X-ray imaging, but this does not allow depth perception and complicates precise manipulation of the guidewire. Our purpose was to develop a novel method for guidewire manipulation by establishing stereoscopic perception in coronary angiography (CAG), as described in our previous study, and thereby improve the precision and success rate of PCI.
methodsBased on establishment of stereo perception in CAG, we used digital subtraction angiography (DSA) with gantry rotation and simulation with UG NX software to determine the orientation of the guidewire tip and the relative positions of the true lumen and false lumen. We then performed verification using a highly realistic 3D-printed transparent silicone model of the human heart and coronary arteries. By manipulating the guidewire in various branches of the model of the coronary artery, we identified the directional torque of wire rotation and simulated this using UG NX software. A preliminary trial with unidirectional rotation was conducted in which one interventionist performed 60 guidewire manipulations (30 before and 30 after training) in a 3D-printed heart model to quantify changes in directional accuracy.
resultsThe results confirmed that the orientation of the distal tip of the guidewire and the relative positions of the true and false lumens were accurately determined using DSA with gantry rotation and simulation with UG NX software. We also validated the consistency of rotational torque within the coronary artery lumen, irrespective of vessel twisting and deformation. The preliminary trial demonstrated a higher success rate (93.3% vs. 60%, p < 0.01) after training.
conclusionOur novel method significantly improved the accuracy of guidewire manipulation in an in vitro model. This method therefore has the potential to enhance PCI outcome, and warrants further examination by clinical trials.