Evidence map›Paper›PMID 41178297›Full record

ArticleCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2026

Guidewire Manipulation Based on Establishment of Stereo Perception in Percutaneous Coronary Intervention.

Miao Chen, Huiqiang Zhao, Xiantao Song

Abstract read
In one paragraph

Article in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Guidewire Manipulation Based on Establishment of Stereo Perception in Percutaneous Coronary Intervention.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Miao ChenDepartment of Emergency, Beijing Friendship Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0001-6620-5488
Huiqiang ZhaoDepartment of Cardiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0001-8920-5640
Xiantao SongDepartment of Cardiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.ORCID https://orcid.org/0000-0003-0980-7014

Funding

The authors received no specific funding for this work.
6 · The paper itself

Abstract

backgroundTraditional percutaneous coronary intervention (PCI) relies on two-dimensional X-ray imaging, but this does not allow depth perception and complicates precise manipulation of the guidewire. Our purpose was to develop a novel method for guidewire manipulation by establishing stereoscopic perception in coronary angiography (CAG), as described in our previous study, and thereby improve the precision and success rate of PCI.

methodsBased on establishment of stereo perception in CAG, we used digital subtraction angiography (DSA) with gantry rotation and simulation with UG NX software to determine the orientation of the guidewire tip and the relative positions of the true lumen and false lumen. We then performed verification using a highly realistic 3D-printed transparent silicone model of the human heart and coronary arteries. By manipulating the guidewire in various branches of the model of the coronary artery, we identified the directional torque of wire rotation and simulated this using UG NX software. A preliminary trial with unidirectional rotation was conducted in which one interventionist performed 60 guidewire manipulations (30 before and 30 after training) in a 3D-printed heart model to quantify changes in directional accuracy.

resultsThe results confirmed that the orientation of the distal tip of the guidewire and the relative positions of the true and false lumens were accurately determined using DSA with gantry rotation and simulation with UG NX software. We also validated the consistency of rotational torque within the coronary artery lumen, irrespective of vessel twisting and deformation. The preliminary trial demonstrated a higher success rate (93.3% vs. 60%, p < 0.01) after training.

conclusionOur novel method significantly improved the accuracy of guidewire manipulation in an in vitro model. This method therefore has the potential to enhance PCI outcome, and warrants further examination by clinical trials.

Indexed as

Cardiac CathetersCoronary AngiographyCoronary VesselsPercutaneous Coronary InterventionAngiography, Digital SubtractionEquipment DesignHumansModels, AnatomicModels, CardiovascularPredictive Value of TestsPrinting, Three-DimensionalRadiographic Image Interpretation, Computer-AssistedRotationTorque3D wiring techniquescoronary angiographycoronary artery diseasepercutaneous coronary interventionstereo perception

Identifiers

PMID41178297
PMCPMC12775199

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.