Evidence map›Paper›PMID 41178260›Full record

ArticleActa oncologica (Stockholm, Sweden)2025

Collimated and non-collimated proton minibeam irradiation using SIRMIO: a simulation study.

Fardous Reaz, Ze Huang, Marco Pinto, Jonathan Bortfeldt, Niels Bassler, Katia Parodi

Abstract read
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fardous ReazDepartment of Clinical Medicine, Aarhus University, Aarhus, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark. fardous@clin.au.dk.ORCID 0009-0002-8332-9655
Ze HuangDepartment of Medical Physics, Ludwig-Maximilians Universität München (LMU Munich), Munich, Germany.ORCID 0000-0002-1533-8851
Marco PintoDepartment of Medical Physics, Ludwig-Maximilians Universität München (LMU Munich), Munich, Germany.ORCID 0000-0001-6835-2561
Jonathan BortfeldtDepartment of Medical Physics, Ludwig-Maximilians Universität München (LMU Munich), Munich, Germany.ORCID 0000-0002-0777-985X
Niels BasslerDepartment of Clinical Medicine, Aarhus University, Aarhus, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-4160-1078
Katia ParodiDepartment of Medical Physics, Ludwig-Maximilians Universität München (LMU Munich), Munich, Germany.ORCID 0000-0001-7779-6690

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeSuccessful clinical integration of pMBRT requires comprehensive investigations of the relationship between various pMBRT parameters and their associated biological effects. Such investigations are critically dependent on small animal models. Therefore, a state-of-the-art small animal irradiation platform like SIRMIO (Small Animal Proton Irradiator for Research in Molecular Image-guided Radiation-Oncology), capable of delivering precisely controlled spatially fractionated doses, is highly desirable for advancing preclinical pMBRT research. MATERIAL AND

methodsThis in silico study evaluates the SIRMIO beamline's capability to deliver beams essential for pMBRT experiments. We used Geant4-based Monte Carlo simulations to investigate two configurations: one without a collimator, and one using a 30 mm thick brass multislit collimator (MSC). For both configurations, we examined center-to-center (CTC) of 3, 4, and 5 mm, with a constant 1 mm slit width when MSC is used.

resultsThe SIRMIO beamline can effectively generate spatially fractionated dose profiles with varying CTC. Without a collimator, sufficient dose contrast for pMBRT can be achieved with CTC of 4 mm and above, as evidenced by peak-to-valley dose ratios (PVDR) of 3.44 and 6.57 for 4 and 5 mm CTC, respectively. MSC further enhances dose contrast, achieving PVDR of 11.3, 20.7, and 28.7 for 3, 4, and 5 mm CTC, respectively. Furthermore, we explored interlacing beams as a means of achieving a uniform target dose while preserving dose contrast in normal tissue, demonstrating the potential of this approach using the SIRMIO beamline.

interpretationThe SIRMIO platform can be a viable option for pMBRT experiments.

Indexed as

Proton TherapyRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedAnimalsComputer SimulationDose Fractionation, RadiationHumansMonte Carlo MethodRadiotherapy Dosage

Identifiers

PMID41178260
PMCPMC12593933

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked