Evidence map›Paper›PMID 41178022›Full record

ArticleActa oncologica (Stockholm, Sweden)2025

3D Swin Transformer for patient-specific proton dose prediction of brain cancer patients.

Anne Haahr Andresen, Yasmin Lassen-Ramshad, Slávka Lukacova, Christian Rønn Hansen, Jesper Folsted Kallehauge

Abstract read
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Anne Haahr AndresenDepartment of Clinical medicine, Arhus University, Aarhus, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark. anan@clin.au.dk.ORCID 0009-0004-3974-5111
Yasmin Lassen-RamshadDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-4992-3231
Slávka LukacovaDepartment of Clinical medicine, Arhus University , Aarhus, Denmark; Department of Oncology, Aarhus University Hospital, Aarhus, Denmark.ORCID 0000-0002-2875-095X
Christian Rønn HansenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Oncology, Odense University Hospital, Odense, Denmark; Institute of Clinical Research, University of Southern Denmark, Odense, Denmark.ORCID 0000-0001-5716-6069
Jesper Folsted KallehaugeDepartment of Clinical medicine, Arhus University , Aarhus, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark].ORCID 0000-0003-3705-5390

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeAccurate dose plans in proton radiotherapy with consistent target in complex anatomical regions such as the brain are crucial. This study investigates a Swin Transformer-based deep learning model for voxel-wise dose prediction in brain cancer proton therapy, evaluating its spatial and dosimetric fidelity against clinically delivered plans. Patient/material and methods: A cohort of 206 patients with primary brain tumors were retrospectively analyzed. Dual-energy computed tomography (CT) scans, clinical contours, and corresponding proton dose plans were used to train and test a 3D Swin Transformer integrated within a UNet architecture. The model was evaluated on an independent test set (n = 20) using 3D gamma analysis (3%/3 mm), mean absolute error (MAE), and clinical target volume (CTV) coverage (V95%). Mean dose-volume histograms (DVHs) were compared across CTV.

resultsThe model achieved a median gamma pass rate of 99.8% within the CTV (range: 78.6-100%), 83.2% outside the CTV (range: 52.3-99.8%), and a whole-volume median pass rate of 90.0% (range: 53.7-99.8%). The median MAE was 0.72 Gy (range: 0.2816-1.8966 Gy). Predicted dose distributions preserved high-dose conformity, with a median of V95% of 97.9% (range: 78.8-100%). DVH curves closely matched the clinical reference plans across all evaluated structures.

interpretationThe proposed Swin Transformer-based model is a step toward accurate, anatomy-aware dose prediction for brain tumor proton therapy. Future work will address prospective validation and optimization for clinical deployment.

Indexed as

Brain NeoplasmsDeep LearningImaging, Three-DimensionalProton TherapyRadiotherapy Planning, Computer-AssistedAdultAgedFemaleHumansMaleMiddle AgedOrgans at RiskRadiotherapy DosageRetrospective StudiesTomography, X-Ray Computed

Identifiers

PMID41178022
PMCPMC12593929

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.