Evidence map›Paper›PMID 41174925›Full record

Trial reportJournal of diabetes science and technology2025

A Pilot Outpatient Assessment of a Fully Closed-Loop Insulin and Pramlintide System.

Madison Odabassian, Michael A Tsoukas, Elisa Cohen, Melissa-Rosina Pasqua, Joanna Rutkowski, Ahmad Haidar

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Journal of diabetes science and technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Madison OdabassianDepartment of Biomedical Engineering, McGill University, Montreal, QC, Canada.ORCID 0009-0008-9866-7589
Michael A TsoukasDivision of Endocrinology, McGill University Health Centre, Montreal, QC, Canada.ORCID 0000-0002-8326-7274
Elisa CohenDepartment of Biomedical Engineering, McGill University, Montreal, QC, Canada.ORCID 0009-0001-1947-9301
Melissa-Rosina PasquaDivision of Endocrinology, McGill University Health Centre, Montreal, QC, Canada.ORCID 0000-0003-2389-9066
Joanna RutkowskiDepartment of Biomedical Engineering, McGill University, Montreal, QC, Canada.
Ahmad HaidarDepartment of Biomedical Engineering, McGill University, Montreal, QC, Canada.ORCID 0000-0002-6700-0385

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundType 1 diabetes is treated with exogenous insulin using multiple daily injections or insulin pumps. However, both strategies require carbohydrate counting for prandial insulin dosing, which is both burdensome and error prone.

methodsWe conducted a pilot, randomized, controlled study to eliminate carbohydrate counting in adults (n = 12, 7 females, age 39.5 [15.1], HbA1c 7.4% [0.6]) using an automated insulin and pramlintide fully closed-loop system. The interventions included five arms during which participants underwent 14 hours of outpatient, free-living, supervised experiments of (1) faster aspart with carbohydrate counting (control), faster aspart and pramlintide without carbohydrate counting at (2) 8 µg/U and (3) 10 µg/U ratios, and aspart and pramlintide without carbohydrate counting at (4) 8 µg/U and (5) 10 µg/U ratios.

resultsThe median time in target range (3.9-10.0 mmol/L) with the control arm was 78.6 [65.3-92.9], compared with 76.2 [64.6-86.9] and 78.8 [68.8-86.0] with the fully closed-loop faster aspart and pramlintide systems at 8 and 10 µg/U ratios, respectively, and compared with 65.9 [59.9-83.6] and 77.4 [72.1-82.7] with the fully closed-loop aspart and pramlintide systems at 8 and 10 µg/U ratios, respectively. Times spent below 3.9 and 3.0 mmol/L were numerically higher with the fully closed-loop aspart and pramlintide systems than the control arm. None of the differences were statistically significant.

conclusionsThis study suggests that automated insulin and pramlintide systems have the potential to alleviate carbohydrate counting without degrading time in range. A longer and larger study is underway.

Indexed as

Diabetes Mellitus, Type 1Hypoglycemic AgentsInsulinInsulin Infusion SystemsIslet Amyloid PolypeptideAdultBlood GlucoseFemaleGlycated HemoglobinHumansInsulin AspartMaleMiddle AgedOutpatientsPilot ProjectsBlood GlucoseGlycated HemoglobinHypoglycemic AgentsInsulinInsulin AspartIslet Amyloid Polypeptidepramlintidecarbohydrate countingclosed-loop delivery systemsfully closed-looppramlintidetype 1 diabetes

Identifiers

PMID41174925
PMCPMC12678853

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked