Evidence map›Paper›PMID 41174605›Full record

ArticleBMC oral health2025

Four-dimensional imaging in teleorthodontics - analysis of accuracy in patients with dentofacial deformities compared with controls.

Tim-Boyke Janssen, Jérémy Mouchoux, Bernhard Wiechens, Henning Schliephake, Philipp Meyer-Marcotty, Anja Quast

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Tim-Boyke JanssenDepartment of Orthodontics, University Medical Center Goettingen, Göttingen, Germany.
Jérémy MouchouxDepartment of Orthodontics, University Medical Center Goettingen, Göttingen, Germany.
Bernhard WiechensDepartment of Orthodontics, University Medical Center Goettingen, Göttingen, Germany.
Henning SchliephakeDepartment of Maxillofacial Surgery, University Medical Center Goettingen, Göttingen, Germany.
Philipp Meyer-MarcottyDepartment of Orthodontics, University Medical Center Goettingen, Göttingen, Germany.
Anja QuastDepartment of Orthodontics, University Medical Center Goettingen, Göttingen, Germany. anja.quast@med.uni-goettingen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTeleorthodontics may offer benefits to both patients and providers in terms of accessibility, efficiency, and quality of care. Therefore, there is an increasing need for accurate, noninvasive monitoring technologies. The present study evaluated the accuracy of a mobile device for four-dimensional imaging in capturing dynamic facial movements and its potential application in orthodontic patients with severe dentofacial deformities.

methodsIn this prospective clinical study, facial movements of 30 adult orthodontic patients (dentofacial deformity: n = 20, controls: n = 10) were captured to evaluate the accuracy of a 4D mobile camera system. Imaging was conducted via Intel RealSense D415 in three settings: (1) with high-accuracy preset, (2) with medium-density presets, and (3) with additional tracking software. The stationary system Canfield Vectra H5 served as the gold standard. Each patient was asked to perform three movements: maximum smiling, lip pursing, and cheek puffing. Accuracy was assessed by the root mean square (RMS).

resultsIn total, 270 4D sequences were analyzed. Overall, the RMS between the 4D sequences and the gold standard were smaller than 1 mm (p < .001). The (a) high-accuracy setting results in a significantly lower RMS than does the (b) medium-density setting (p < .001). Setting (c) resulted in higher RMS values for lip pursing and cheek puffing than setting (a) or (b). Among the movements, smiling presented the greatest RMS, whereas lip pursing and cheek puffing presented similarly small differences. Class-wise comparisons did not reveal evidence of differences.

conclusionThe present study demonstrated that the portable 4D camera system achieved sub-millimeter accuracy in patients with dentofacial deformities. Accuracy was influenced by the recording preset, whereas additional software did not improve performance. Within the limits of this pilot study, the device showed adequate recording quality to support feasibility in teleorthodontic applications for capturing facial dynamics. Future research should evaluate its usability, cost-effectiveness, and potential integration with artificial intelligence to extend clinical applications.

Indexed as

Dentofacial DeformitiesOrthodonticsTelemedicineAdultFemaleHumansImaging, Three-DimensionalMaleMotion CaptureProspective StudiesYoung AdultImage processingMalocclusionRemote consultationTelemedicine

Identifiers

PMID41174605
PMCPMC12579406

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked