ArticleNeuroradiology2025
Feasibility, safety and efficacy of Woven EndoBridge embolization of intracranial aneurysms with the 2 mm height variants.
Article in Neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- The natural history of untreated small (< 5 mm) intracranial aneurysms: a five-year angiographic follow-up study.Neurosurgical review · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeSmall, shallow aneurysms (SSAs) present technical challenges for endovascular treatment with the risk of aneurysm perforation and coil protrusion. The Woven EndoBridge (WEB) device, particularly the lowest height of 2 mm variant, offers a potential alternative option for these aneurysms. This multicenter study evaluates the feasibility, safety and efficacy of the WEB for SSAs ≤ 4.1 mm width.
methodsA total of 103 aneurysms (mean size: 3.4 ± 1.1 mm, 67 [65%] bifurcation) treated with WEB single-layer sizes ranging from 3 × 2 mm to 4.5 × 2 mm were retrospectively analyzed. Data on procedural success, complications, and angiographic outcomes were collected. The incidence and potential strategies to counteract WEB protrusion were evaluated.
resultsWEB deployment was successful in 97 (94%) cases, but WEB protrusion occurred in 12 (12%) cases. Strategies to counteract WEB protrusion were change to another endovascular technique (n = 4), additional stent implantation (n = 4), change to a smaller WEB size (n = 3), and repositioning of the WEB (n = 1). Procedural thromboembolic complications occurred in 4 (4%) cases, of which 3 were due to protrusion of the WEB, but all were asymptomatic. Two hemorrhagic complications (2%), caused by aneurysm perforation with the microwire in the first case and with the folded WEB tip in the second, resulted in procedural morbidity (2%). Complete and adequate occlusion rates were 82% (42/51) and 90% (46/51) at 6 months and 76% (19/25) and 88% (22/25) at 12 months, respectively.
conclusionThe 2 mm height WEB demonstrated feasibility and efficacy in the treatment of SSAs with good safety results, making it a viable alternative endovascular option for SSAs.