ArticleBrazilian dental journal2025
c
Article in Brazilian dental journal, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We aimed to evaluate the effect of varying the tube current and the Metal Artifact Reduction (MAR) tool on the detection of the missing second mesiobuccal (MB2) canal. Forty maxillary molars (20 with and 20 without MB2) were selected and confirmed by micro-CT. The teeth underwent endodontic preparation, with the canals filled using gutta-percha and a silver-palladium metal post. CBCT scans were acquired using the OP300 Maxio system (voxel size: 0.085 mm, FOV: 50 x 50 mm) at 4 mA, 6.3 mA, and 12.5 mA, with and without MAR activation. The areas under the receiver operating characteristic curves (AUCs), sensitivities, and specificities were calculated for five examiners and compared using two-way ANOVA (p < 0.05). Intra- and interexaminer agreements were assessed using the weighted Kappa test. The AUC values ranged from 0.90 to 0.94, sensitivity from 0.75 to 0.78, and specificity from 0.89 to 0.95. Intra- and interexaminer indices ranged from moderate to substancial. Based on the tube current settings or MAR activation, there were no significant differences in the MB2 canal detection. Therefore, varying the tube current and MAR tool activation did not affect MB2 canal detection, with values close to 4 mA without MAR activation recommended in this scenario to reflect a better dose-benefit ratio.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.