ArticlePloS one2025
Network reconfiguration and DG based compensation of Wolaita Sodo distribution system by using particle swarm optimisation.
Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Improving voltage profiles and reducing power losses are critical challenges in modern distribution systems, especially in real, unbalanced and weakly interconnected grids. This study presents a novel application of simultaneous network reconfiguration and distributed generation (DG) placement using Particle Swarm Optimization (PSO) to the Wolaita Sodo distribution network in Ethiopia. Unlike most prior works conducted on IEEE standard feeders, this research uses actual network topology, load data, conductor parameters and operational constraints from a real Ethiopian distribution system. The optimization problem considers radiality constraints, DG size limits and voltage and current limits, with objectives of minimizing active/reactive power losses, improving voltage profiles and maximizing economic benefits. A backward-forward sweep load flow method evaluates network performance under four scenarios: base case, reconfiguration only, DG placement only and simultaneous implementation. Results show that the proposed method reduces active power losses by 72.064%, decreases voltage deviation from 24.63% to 4.5% and improves the minimum bus voltage from 0.7537 pu to 0.9550 pu. The annual financial savings of 16.3956 million ETB yield a payback period of six years. This grouping of real-network data, simultaneous optimization, and integrated techno-economic analysis offers a practical and replicable decision-support tool for utilities in emerging power systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.