Evidence map›Paper›PMID 41164753›Full record

ArticleFrontiers in pharmacology2025

Comparison of oxcarbazepine metabolite concentrations measured by EMIT-based Siemens Viva-ProE

Ming Chen, Rong-Qi Lin, Yun-Yi Mao, Ying-Bin Huang, Jun-Nan Wu, Xue-Yong Li, Xue-Mei Wu, Yu Cheng, Hong-Qiang Qiu

Abstract read
In one paragraph

Article in Frontiers in pharmacology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ming Chen *Department of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Rong-Qi Lin *Department of Pharmacy, Shanghang County Hospital, Shanghang, China.
Yun-Yi MaoDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Ying-Bin HuangDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Jun-Nan WuDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Xue-Yong LiDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Xue-Mei WuDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Yu ChengDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.
Hong-Qiang QiuDepartment of Pharmacy, Fujian Medical University Union Hospital, Fuzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Therapeutic drug monitoring (TDM) of oxcarbazepine's active metabolite, the monohydroxy derivative (MHD), is essential for effective seizure management. Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) is considered the gold standard for MHD quantification, its technical complexity restricts widespread clinical utility. The Siemens Viva-ProE Objectives: This study established and validated an LC-MS/MS method for quantifying MHD in plasma and assessed the correlation and concordance of SVPS measurements using concentration-specific Deming regression. The objective was to evaluate the feasibility of replacing LC-MS/MS with SVPS for TDM LC-MS/MS in clinical practice. Methods: A validated LC-MS/MS method (linear range: 0.18-39.30 μg/mL; intra/inter-day RSD < 15%) and SVPS (measurable range: 0.00-50.00 μg/mL) were applied to analyze 158 plasma samples. Correlation and concordance between the methods were assessed using Spearman's correlation, intraclass correlation coefficient (ICC), linear regression and Deming regression, Bland-Altman analysis, and Wilcoxon signed-rank tests. Stratified subgroup analyses, classified as low (<12 μg/mL), medium (12-22 μg/mL), and high (>22 μg/mL) concentration ranges, were conducted to evaluate the clinical acceptability of corrected SVPS values. Results: SVPS demonstrated a concentration-dependent positive bias (+13.04%) relative to LC-MS/MS. Despite this bias, strong overall correlation and concordance were observed ( Conclusion: While uncorrected SVPS results exhibit a systematic bias that produces direct interchangeability with LC-MS/MS, applying a concentration-specific Deming correction enables clinically reliable TDM of MHD at concentrations below 22 μg/mL. However, method optimization is still required for accurate quantification in the high-concentration range.

Indexed as

10-hydroxycarbazepineEMITLC-MS/MSoxcarbazepineViva-ProE®

Identifiers

PMID41164753
PMCPMC12558792

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.