Evidence map›Paper›PMID 41164320›Full record

ArticleJournal of experimental orthopaedics2025

High coronal alignment accuracy and satisfactory early outcomes using augmented reality assisted kinematic alignment in total knee arthroplasty.

Giorgio Cacciola, Francesco Bosco, Daniele Vezza, Matteo Schirò, Francesco Carturan, Gianpaolo Gazziero, Marco Bufalo, Luigi Sabatini

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Giorgio CacciolaDepartment of Orthopaedics and Traumatology University of Turin Turin Italy.
Francesco BoscoDepartment of Precision Medicine in Medical, Surgical and Critical Care (Me.Pre.C.C.) University of Palermo Palermo Italy.ORCID https://orcid.org/0000-0001-8306-1869
Daniele VezzaDepartment of Robotic and Mini-Invasive Orthopaedic Surgery Humanitas "Gradenigo" Hospital Turin Italy.
Matteo SchiròDepartment of Robotic and Mini-Invasive Orthopaedic Surgery Humanitas "Gradenigo" Hospital Turin Italy.
Francesco CarturanDepartment of Orthopaedics and Traumatology University of Turin Turin Italy.
Gianpaolo GazzieroDepartment of Orthopaedics and Traumatology University of Turin Turin Italy.
Marco BufaloDepartment of Orthopaedics and Traumatology University of Turin Turin Italy.
Luigi SabatiniDepartment of Robotic and Mini-Invasive Orthopaedic Surgery Humanitas "Gradenigo" Hospital Turin Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Accurate component positioning in total knee arthroplasty (TKA) is critical for implant longevity and patient satisfaction. Augmented reality (AR)-based navigation systems offer enhanced precision and intraoperative versatility. This study evaluated the accuracy of component positioning, implant sizing and short-term clinical outcomes of a novel AR-assisted navigation system (NextAR, Medacta International) in TKA using a modified kinematic alignment (KA) technique. Methods: Forty-one consecutive patients underwent primary TKA using AR-assisted navigation with ≥12-month follow-up. Preoperative CT-based 3D planning optimised cut orientation and component placement. All received a cemented medial pivot prosthesis (GMK Sphere) with full femoral resurfacing following a KA protocol. Tibial cuts were guided intraoperatively by real-time ligament balancing. Planned versus achieved positions were compared on radiographs. Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), forgotten joint score (FJS) and range of motion (ROM) were recorded pre- and postoperatively and analysed using paired Results: The average difference between planned and postoperative alignment was 0.05° ± 0.76° for LDFA, 0.1° ± 0.6° for MPTA, -0.5 ± 1.7° for femoral component flexion, and 0.3° ± 1.3° for PTS. Root mean square errors were 0.75°, 1.23°, 1.73° and 1.34°, respectively. Postoperative HKA improved from 174.3° ± 3.4° to 177.8° ± 2.1° ( Conclusions: AR-based navigation in modified KA-TKA ensured accurate LDFA restoration and femoral sizing, with good short-term outcomes. Variability remained in MPTA, femoral flexion and PTS. Although no coronal recuts were needed, two tibial recuts for tight extension gaps highlight areas for system refinement. Level of Evidence: Level IV.

Indexed as

augmented realitycomponent positioningcomputer‐assisted surgerykinematic alignmentoutcomessurgical precisiontotal knee arthroplasty

Identifiers

PMID41164320
PMCPMC12560251

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.