Evidence map›Paper›PMID 41163771›Full record

ArticleJournal of medical physics

Validation of Treatment Planning Systems based on Dose Calculation Accuracy for Extended SSD Total Body Irradiation with and without Beam Spoiler.

Jayapalan Krishnan, Achuth S Nayak, Nisma Farooq, M Dinesh, Suryanarayana Kunikullaya, Muhammed Shafeeque

Abstract read
In one paragraph

Article in Journal of medical physics. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jayapalan KrishnanDepartment of Radiation Oncology, Zulekha Yenepoya Institute of Oncology, Yenepoya Medical College Hospital, Yenepoya (Deemed to be University), Mangalore, Karnataka, India.
Achuth S NayakDepartment of Radiation Oncology, Zulekha Yenepoya Institute of Oncology, Yenepoya Medical College Hospital, Yenepoya (Deemed to be University), Mangalore, Karnataka, India.
Nisma FarooqDepartment of Radiation Oncology, Zulekha Yenepoya Institute of Oncology, Yenepoya Medical College Hospital, Yenepoya (Deemed to be University), Mangalore, Karnataka, India.
M DineshDepartment of Radiation Oncology, Zulekha Yenepoya Institute of Oncology, Yenepoya Medical College Hospital, Yenepoya (Deemed to be University), Mangalore, Karnataka, India.
Suryanarayana KunikullayaDepartment of Radiation Oncology, Zulekha Yenepoya Institute of Oncology, Yenepoya Medical College Hospital, Yenepoya (Deemed to be University), Mangalore, Karnataka, India.
Muhammed ShafeequeDepartment of Radiation Oncology, Zulekha Yenepoya Institute of Oncology, Yenepoya Medical College Hospital, Yenepoya (Deemed to be University), Mangalore, Karnataka, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: This study aimed to confirm the accuracy of the dose calculation by commercially available treatment planning system (TPS) at the extended SSD = 350 cm with and without beam spoiler configurations. Materials and Methods: Two extended SSD plans, one without a beam spoiler and another with a beam spoiler, were created on a virtual phantom in Eclipse TPSs for 6 MV photon beam. Using dosimetry tools, percentage depth doses (PDDs) and in-line profiles of both plans were generated. Beam properties of the TPS calculated PDDs and profiles were compared with manually calculated and measured PDDs and profiles. Reference depth dose was calculated in two different phantoms and measured using an ion chamber and TLDs. Results: At the extended SSD setup, the TPS calculated and measured PDD with and without beam spoiler were in agreement within 2%. This agreement was observed at the surface and in the buildup region as well. Flatness and symmetry of the profiles with and without beam spoiler were within ± 3%. The TPS calculated dose at a reference depth in a homogeneous and a heterogeneous phantom was agreed with measured dose using an ion-chamber and TLDs. Conclusion: This study validated the TPS for extended SSD total body irradiation (TBI) dose calculation with and without beam spoiler. Developing computed tomography based field in field plan for homogeneous dose distribution may be feasible. This technique may allow us to treat extended SSD TBI in less time while maintaining dose calculation accuracy.

Indexed as

extended source-to-surface distance profile with beam spoilerextended source-to-surface distance total body irradiation using treatment planning systemsExtended SSD percentage depth dose with beam spoiler

Identifiers

PMID41163771
PMCPMC12560995

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.