ArticleScientific reports2025
Novel Helmholtz resonators parallel to lateral closed resonators for sensing applications.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Reliability analysis of different geometric configurations of Helmholtz resonators for a sustainable performance.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study looks into the design of Helmholtz resonators along with lateral closed resonators for sensing applications, mainly for gas sample detection. A periodic parallel arrangement of both Helmholtz resonator and closed resonators was studied, while one resonator was defected to study the performance of the system. A relevant study was carried out in terms of numerical simulations with available data in the finite element method that give insight into the acoustic wave transmission and resonant frequencies of the system with or without defect. The study presented that due to the defect, highly localized modes deriving at lower spatial frequencies are induced within the system, making it highly sensitive to fine shifts of frequency. This sensitivity enables it to detect a wide variety of gas samples. Further, increasing the number of periods to 9 resulted in optimal performance, with significant improvements in sensitivity, quality factor, and detection limit. The study discusses the impact of geometric parameters and gas properties on system sensitivity, quality factor, and detection limit, indicating high potential for precision in sensing use for environmental monitoring and biosensing. The proposed sensor demonstrates exceptional selectivity in gas mixtures and maintains robust stability across a wide range of operating temperatures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.