ArticleJournal of thoracic disease2025
Efficacy of a novel steerable chest tube system in a swine model of hemothorax.
Article in Journal of thoracic disease, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Thoracostomy tubes (chest tubes) are the standard of care for thoracic trauma, including hemothorax. However, traditional chest tubes are susceptible to occlusion and lack the ability to be repositioned once inserted. This can lead to further life-threatening issues, such as retained hemothorax. Here we describe the investigation of a novel steerable chest tube, the SAM repositionable chest tube (RCT), which is designed with two-axis manipulation for effective drainage of the pleural space while maintaining sterility. We hypothesized that the treatment of hemothorax with RCT would result in an increase of evacuated fluid from the pleural space and a decrease of residual clot compared to a traditional chest tube. Using a swine model of retained hemothorax developed by our laboratory, six male swine (78.2±2.1 kg) were randomized for an RCT and traditional (straight 28-Fr chest tube) side of the pleural cavity. To create a hemothorax, 2 L of autologous blood was withdrawn and 1 L was infused into each side of the pleural cavity. Evacuated blood volume was recorded for both devices for the entirety of the experiment, and residual clot was measured upon necropsy. At end of study, the RCT demonstrated significantly greater blood evacuation (585±65 mL) compared to the traditional chest tube (436±100 mL, P=0.03). Although the RCT reduced retained clot burden (436±95
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.