ArticleMicromachines2025
Thermal Gas Flow Sensor Using SiGe HBT Oscillators Based on GaN/Si SAW Resonators.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper presents a thermal gas flow sensing system, from surface acoustic wave (SAW) temperature sensor to oscillation circuit and multi-module miniaturization integration. A single-port GaN/Si SAW resonator with single resonant mode and excellent characteristics was fabricated. Combined with an in-house-developed SiGe HBT, a temperature-sensitive high-frequency oscillator was constructed. Under constant temperature control, system-level flow measurement was achieved through dual-oscillation configuration and modular integration. The fabricated SAW device shows a temperature coefficient of frequency (TCF) -28.29 ppm/K and temperature linearity 0.998. The oscillator operates at 1.91 GHz with phase noise of -97.72/-118.62 dBc/Hz at 10/100 kHz offsets. The system demonstrates excellent dynamic response and repeatability, directly measuring 0-50 sccm flows. For higher flows (>50 sccm), a shunt technique extends the test range based on the 0-10 sccm linear region, where response time is <1 s with error <0.9%. Non-contact operation ensures high stability and long lifespan. The sensor shows outstanding performance and broad application prospects in flow measurement.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.