ArticleMicromachines2025
Wearable Flexible Wireless Pressure Sensor Based on Poly(vinyl alcohol)/Carbon Nanotube/MXene Composite for Health Monitoring.
Article in Micromachines, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Neutral-Axis TiSensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Accurate pressure monitoring is crucial for both human body applications and intelligent robotic arms, particularly for whole-body motion monitoring in human-machine interfaces. Conventional wearable electronic devices, however, often suffer from rigid connections, non-conformity, and inaccuracies. In this study, we propose a high-precision wireless flexible sensor using a poly(vinyl alcohol)/single-walled carbon nanotube/MXene composite as the sensitive material, combined with a randomly distributed wrinkle structure to accurately monitor pressure parameters. To validate the sensor's performance, it was used to monitor movements of the vocal cords, bent fingers, and human pulse. The sensor exhibits a pressure measurement range of approximately 0-130 kPa and a minimum resolution of 20 Pa. At pressures below 1 kPa, the sensor exhibits high sensitivity, enabling the detection of transient pressure changes. Within the pressure range of 1-10 kPa, the sensitivity decreases to approximately 54.71 kPa
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.