Evidence map›Paper›PMID 41155124›Full record

ArticleBioengineering (Basel, Switzerland)2025

Computational Study of Tesla Valve Design for Vesico-Amniotic Shunt to Manage Lower Urinary Tract Obstruction and Pleural Effusion.

SaiSri Nakirekanti, Varun Chandra Sarkonda, Janet Dong, Donglu Shi, Ahmad M Alsaghir, Je-Hyeong Bahk, Braxton Forde

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

SaiSri NakirekantiDepartment of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA.
Varun Chandra SarkondaDepartment of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA.
Janet DongDepartment of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA.
Donglu ShiDepartment of Biomedical Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA.ORCID 0000-0002-0837-7780
Ahmad M AlsaghirDepartment of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA.
Je-Hyeong BahkDepartment of Mechanical and Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, USA.ORCID 0000-0002-5808-2227
Braxton FordeDepartment of Obstetrics and Gynecology, College of Medicine, University of Cincinnati, Cincinnati, OH 45267, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fetal lower urinary tract obstruction (LUTO) and pleural effusion are conditions that can disrupt fetal growth and lead to fetal death. LUTO inhibits the formation of amniotic fluid, which is vital for lung development, while pleural effusions can compress the fetal heart, potentially causing fatal cardiac failure. To manage these conditions, a fetal shunt (vesico-amniotic shunt) is placed inside the fetal bladder. This paper presents a study on a new design incorporating a Tesla valve in the shunt. Six groups of Tesla valves with loop angles of 50 degrees and 60 degrees, and different end dimensions, are examined and evaluated in terms of the urine flow rate from the fetal bladder into the amniotic cavity, the pressure buildup between the two sides, and their potential in developing fetal bladder muscles. A mathematical method is used to compare diode characteristics, analyze flow rates, identify the Tesla valve angle, determine the Reynolds number, and assess diodicity. The Computational Fluid Dynamics (CFD) method is also employed to verify calculation results and simulate fluid behavior inside the Tesla valve. Combining the calculations and simulations, a 50-degree Tesla valve with specific dimensions showed the best performance and will be the optimal design for the fetal shunt.

Indexed as

CFDdiodicityfetal shuntLUTOReynolds numberTesla valvevesico-amniotic shunt

Identifiers

PMID41155124
PMCPMC12561101

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials