Evidence map›Paper›PMID 41155087›Full record

ArticleBioengineering (Basel, Switzerland)2025

Innovative Compact Vibrational System with Custom GUI for Modulating Trunk Proprioception Using Individualized Vibration Parameters.

Debdyuti Mandal, John R Gilliam, Sheri P Silfies, Sourav Banerjee

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Debdyuti MandalDepartment of Electrical and Computer Engineering, University of Southern California, Los Angeles, CA 90089, USA.ORCID 0000-0002-9750-7814
John R GilliamPain Research and Intervention Center of Excellence, University of Florida, Gainesville, FL 32611, USA.
Sheri P SilfiesSpine Neuromechanics Laboratory, Department of Physical Therapy, University of Delaware, Newark, DE 19713, USA.ORCID 0000-0002-4120-5358
Sourav BanerjeeDepartment of Mechanical Engineering, University of South Carolina, Columbia, SC 29208, USA.

Funding

Biomedical-Behavioral Interface: Prevention and Developmental Sciences TrainingT32GM081740 · NIGMS · UNIVERSITY OF SOUTH CAROLINA AT COLUMBIA · PI PRINZ, RONALD J · 2008 to 2022
$4.5M
University of Florida Partnerships Across Interdisciplinary Networks: Training through Engineering, epidemiology & Addiction Medicine (UF PAIN TEAM)T90AR085527 · NIAMS · UNIVERSITY OF FLORIDA · PI Kyle D Allen, Yenisel Cruz-Almeida · 2024 to 2026
$1.0M
NIAMS NIH HHS T90 AR085527NIGMS NIH HHS T32 GM081740NIH-NIGMS T32-GM081740
6 · The paper itself

Abstract

Conventional vibrational systems associated with proprioception are mostly equipped with a single standard frequency and amplitude. This feature often fails to show kinesthetic illusion on different subjects, as different individuals respond to different frequencies and amplitudes. Additionally, different muscle groups may also require the flexibility of frequencies and amplitudes. We developed a custom vibrational system that is equipped with flexible frequency and amplitude, adapted to a custom graphical user interface (GUI). Based on the user's criteria, the proposed vibrational system enables a wide range of frequencies and amplitudes that can be swept under a single platform. In addition, the system uses small linear actuators that are wearable and attach to the subject without the need for restrictive straps. The vibrational system was used to model trunk proprioceptive impairment associated with low back pain. Low back pain is the leading cause of disability worldwide. It is mostly associated with impaired postural control of the trunk. For postural control, the somatosensory system transmits proprioceptive (position sense) information from the sensors in the skin, joints, muscles, and tendons. Proprioceptive studies on trunk muscles have been conducted where the application of vibration at a set amplitude and frequency across all participants resulted in altered proprioception and a kinesthetic illusion, but not in all individuals. To assess the feasibility of the system, we manipulated the trunk proprioception of five subjects, demonstrating that the vibrational system is capable of modulating trunk proprioception and the value of customizing parameters of the system to obtain maximal deficits from individual subjects.

Indexed as

actuatorkinesthetic illusionproprioceptionspinal injuryvibrational system

Identifiers

PMID41155087
PMCPMC12561096

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.