Evidence map›Paper›PMID 41155082›Full record

ReviewBioengineering (Basel, Switzerland)2025

Could Novel Spinal Braces with Flexibility, Robotic Components, and Individualized Design Generate Sufficient Biomechanical Treatment Efficacy in Patients with Scoliosis?

Chen He, Jinkun Xie, Rong Pang, Bingshan Hu, Christina Zong-Hao Ma

Abstract readReview
In one paragraph

Review in Bioengineering (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Chen HeSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Jinkun XieSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Rong PangSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Bingshan HuSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
Christina Zong-Hao MaDepartment of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong SAR 999077, China.ORCID 0000-0001-6507-2329

Funding

National Key Research and Development Program of China 2022YFC3601400Shidong hospital 2024KYCX2403
6 · The paper itself

Abstract

backgroundPatients with adolescent idiopathic scoliosis (AIS) require effective bracing to control curve progression. However, most traditional spinal braces commonly pose challenges in terms of undesired bulkiness and restricted mobility. Recent advancements have focused on innovative brace designs, utilizing novel materials and structural configurations to improve wearability and functionality. However, it remains unclear how effective these next-generation braces are biomechanically compared to traditional braces.

objectivesThis review aimed to analyze the design features of next-generation AIS braces and assess their biomechanical effectiveness via reviewing contemporary studies.

methodsStudies on newly designed scoliosis braces over the past decade were searched in databases, including Web of Science, PubMed, ScienceDirect, Wiley, EBCOHost and SpringerLink. The Joanna Briggs Institute Critical Appraisal Checklist for Cohort Studies was adopted to evaluate the quality of the included studies. The data extracted for biomechanical effect analysis included brace components/materials, design principle, interfacial pressure, morphological changes, and intercomparison parameters.

resultsA total of 19 studies encompassing 12 different kinds of braces met the inclusion/exclusion criteria. Clinical effectiveness was reported in 14 studies, with an average short-term Cobb angle correction of 25.4% (range: 12.41-34.3%) and long-term correction of 18.22% (range: 15.79-19.3%). This result aligned broadly with the previously reported efficacy of the traditional braces in short-term cases (range: 12.36-31.33%), but was lower than the long-term ones (range: 23.02-33.6%). Two included studies reported an interface pressure range between 6.0 kPa and 24.4 kPa for novel braces, which was comparable to that of the traditional braces (4.8-30.0 kPa). Additionally, five of six studies reported the trunk asymmetric parameters and demonstrated improvement in trunk alignment.

conclusionsThis study demonstrates that most newly designed scoliosis braces could achieve comparable biomechanical efficacy to the conventional designs, particularly in interface pressure management and Cobb angle correction. However, future clinical adoption of these novel braces requires further improvements of ergonomic design and three-dimensional correction, as well as more investigation and rigorous evidence on the long-term treatment outcomes and cost-effectiveness.

Indexed as

biomechanical effectscoliosissmart bracespinal bracespinal orthosistreatment efficacy

Identifiers

PMID41155082
PMCPMC12561335

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked