Evidence map›Paper›PMID 41153886›Full record

ArticleAnimals : an open access journal from MDPI2025

Are Reusable Dry Electrodes an Alternative to Gelled Electrodes for Canine Surface Electromyography?

Ana M Ribeiro, I Brás, L Caldeira, J Caldeira, C Peham, H Plácido da Silva, João F Requicha

Abstract read
In one paragraph

Article in Animals : an open access journal from MDPI, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ana M RibeiroDepartment of Veterinary Sciences, University of Trás-os-Montes e Alto Douro (UTAD), 5000-801 Vila Real, Portugal.ORCID 0000-0003-0403-1616
I BrásDepartment of Bioengineering, Instituto Superior Técnico, 1049-001 Lisbon, Portugal.
L CaldeiraDepartment of Bioengineering, Instituto Superior Técnico, 1049-001 Lisbon, Portugal.
J CaldeiraDepartment of Bioengineering, Instituto Superior Técnico, 1049-001 Lisbon, Portugal.ORCID 0009-0007-3356-4477
C PehamMovement Science Group, Clinical Centre for Equine Health and Research, Clinical Department for Small Animals and Horses, University of Veterinary Medicine, 1210 Vienna, Austria.ORCID 0000-0002-8363-5751
H Plácido da SilvaDepartment of Bioengineering, Instituto Superior Técnico, 1049-001 Lisbon, Portugal.ORCID 0000-0001-6764-8432
João F RequichaDepartment of Veterinary Sciences, University of Trás-os-Montes e Alto Douro (UTAD), 5000-801 Vila Real, Portugal.ORCID 0000-0002-9463-1625

Funding

Fundação para a Ciência e Tecnologia 10.54499/UIDB/04585/2020 (CiiEM), UIDB/CVT/00772/2020 CECAV, doi:10.54499/UIDB/00772/2020), UIDB/CVT/50008/2020, LA/P/0059/2020, and UID/50008 (Instituto de Telecomunicações).
6 · The paper itself

Abstract

Despite its increasing use in veterinary rehabilitation, practical constraints-such as skin preparation and single-use electrodes-limit the wider adoption of surface electromyography (sEMG). Having conventional pre-gelled Ag/AgCl electrodes as reference, we made a pioneering comparison of the performance of reusable soft polymeric dry electrodes for recording paraspinal muscle activity in dogs during treadmill walking. Twelve clinically healthy Dachshunds from both genders were evaluated under two conditions, namely: (i) dry electrodes on untrimmed hair; and (ii) pre-gelled electrodes after trichotomy. Signals were acquired from the longissimus dorsi muscle at 1 kHz, processed with standardized filtering and rectification, and analyzed in both time and frequency domains. Dry electrodes yielded higher amplitude and Root Mean Square (RMS) values, but slightly lower power spectral density metrics when compared to pre-gelled electrodes. Nevertheless, frequency-domain results were broadly comparable between configurations. Dry electrodes reduce the preparation time, avoid hair clipping, and allow reusability without major signal degradation. While pre-gelled electrodes may still offer marginally superior stability during movement, our results suggest that soft polymeric dry electrodes present a feasible, less invasive, and more sustainable alternative for canine sEMG. These findings support further validation of dry electrodes in clinical populations, particularly for neuromuscular assessment in intervertebral disk disease.

Indexed as

caninedry electrodesmuscle activitysurface electromyography

Identifiers

PMID41153886
PMCPMC12560863

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.