ArticleBiosensors2025
High-Sensitivity Terahertz Biosensor Based on a Multi-Layer Hybrid Structure Consisting of a Defect Mode and Graphene.
Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Enhanced urine refractive index sensing using a defect-engineered one-dimensional photonic crystal.Scientific reports · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A high-sensitivity terahertz (THz) biosensor is proposed in this paper based on a multi-layer hybrid structure consisting of a defect mode and graphene with a truncation layer. This biosensor is based on symmetrical Bragg reflectors with a defect layer and graphene with a truncation layer, which effectively comprise a multi-layer hybrid resonance excitation structure. The high sensitivity of this biosensor is developed through defect mode resonance, and the resonance reflection peak is made sharper and more sensitive by using graphene with a truncation layer. After testing and analysis, the sensitivity of this biosensor structure is greatly affected by the refractive index and thickness of the sensing medium. By setting parameters appropriately, the composite structure can be used as both a liquid biosensor and a gas biosensor, the maximum sensitivity of which can surpass 2000°/RIU, while an FOM value of 22,500 RIU
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.