Evidence map›Paper›PMID 41149314›Full record

ArticleBiosensors2025

Double-Layered Microphysiological System Made of Polyethylene Terephthalate with Trans-Epithelial Electrical Resistance Measurement Function for Uniform Detection Sensitivity.

Naokata Kutsuzawa, Hiroko Nakamura, Laner Chen, Ryota Fujioka, Shuntaro Mori, Noriyuki Nakatani, Takahiro Yoshioka, Hiroshi Kimura

Abstract read
In one paragraph

Article in Biosensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Naokata KutsuzawaMicro/Nano Technology Center, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan.ORCID 0009-0006-0882-3927
Hiroko NakamuraMicro/Nano Technology Center, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan.
Laner ChenMicro/Nano Technology Center, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan.
Ryota FujiokaSCREEN Holdings Co., Ltd., Kyoto 612-8486, Kyoto, Japan.
Shuntaro MoriSCREEN Holdings Co., Ltd., Kyoto 612-8486, Kyoto, Japan.
Noriyuki NakataniSCREEN Holdings Co., Ltd., Kyoto 612-8486, Kyoto, Japan.ORCID 0000-0002-0658-6706
Takahiro YoshiokaTOKYO OHKA KOGYO Co., Ltd., Koza 253-0114, Kanagawa, Japan.
Hiroshi KimuraMicro/Nano Technology Center, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan.ORCID 0000-0003-0623-0248

Funding

Japan Agency for Medical Research and Development JP17be0304204Japan Agency for Medical Research and Development JP22be1004101Japan Society for the Promotion of Science JP18H01849Japan Society for the Promotion of Science JP24K01321
6 · The paper itself

Abstract

Microphysiological systems (MPSs) have emerged as alternatives to animal testing in drug development, following the FDA Modernization Act 2.0. Double-layer channel-type MPS chips with porous membranes are widely used for modeling various organs, including the intestines, blood-brain barrier, renal tubules, and lungs. However, these chips faced challenges owing to optical interference caused by light scattering from the porous membrane, which hinders cell observation. Trans-epithelial electrical resistance (TEER) measurement offers a non-invasive method for assessing barrier integrity in these chips. However, existing electrode-integrated MPS chips for TEER measurement have non-uniform current densities, leading to compromised measurement accuracy. Additionally, chips made from polydimethylsiloxane have been associated with drug absorption issues. This study developed an electrode-integrated MPS chip for TEER measurement with a uniform current distribution and minimal drug absorption. Through a finite element method simulation, electrode patterns were optimized and incorporated into a polyethylene terephthalate (PET)-based chip. The device was fabricated by laminating PET films, porous membranes, and patterned gold electrodes. The chip's performance was evaluated using a perfused Caco-2 intestinal model. TEER levels increased and peaked on day 5 when cells formed a monolayer, and then they decreased with the development of villi-like structures. Concurrently, capacitance increased, indicating microvilli formation. Exposure to staurosporine resulted in a dose-dependent reduction in TEER, which was validated by immunostaining, indicating a disruption of the tight junction. This study presents a TEER measurement MPS platform with a uniform current density and reduced drug absorption, thereby enhancing TEER measurement reliability. This system effectively monitors barrier integrity and drug responses, demonstrating its potential for non-animal drug-testing applications.

Indexed as

Biosensing TechniquesElectric ImpedancePolyethylene TerephthalatesCaco-2 CellsElectrodesHumansMicrophysiological SystemsPolyethylene Terephthalatesgut-on-a-chipIntestinal epithelial modelmicrofluidic devicemicrophysiological system (MPS)polyethylene terephthalate (PET)trans-epithelial electro resistance (TEER)

Identifiers

PMID41149314
PMCPMC12562628

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.