Evidence map›Paper›PMID 41149221›Full record

ArticleBiomimetics (Basel, Switzerland)2025

Efficacy and Safety of Kahook Dual Blade Goniotomy and Trabecular Micro-Bypass Stent in Combination with Cataract Extraction.

Kevin Y Wu, Shu Yu Qian, Lysa Houadj, Michael Marchand

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Preliminary Outcomes of iStent Inject vs Kahook Dual Blade Goniotomy Combined With Phacoemulsification: A Randomized Controlled Trial.Medical science monitor : international medical journal of experimental and clinical research · 2026
    Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kevin Y WuDepartment of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.ORCID 0000-0002-1662-6900
Shu Yu QianFaculty of Medicine, University of Sherbrooke, Sherbrooke, QC J1H 5H3, Canada.
Lysa HouadjFaculty of Medicine, University of Sherbrooke, Sherbrooke, QC J1H 5H3, Canada.
Michael MarchandDepartment of Surgery, Division of Ophthalmology, University of Sherbrooke, Sherbrooke, QC J1G 2E8, Canada.ORCID 0000-0002-1069-630X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In recent years, rapid advancements in glaucoma research have led to the development of more effective treatments of this chronic and irreversible condition. Of these, Kahook Blade Dual (KDB) goniotomy and second-generation trabecular micro-bypass stent (iStent) are two novel biomimetic procedures which have designs inspired by the eye's natural drainage mechanisms. In this retrospective study, we evaluated the safety and effectiveness of both surgeries by including 176 eyes from 110 patients: 142 eyes in the iStent group and 34 in the KDB group. The primary outcomes of this study were the proportions of patients in each group attaining a 20% reduction in IOP and a post-operative IOP < 19 mmHg. At the last follow-up, a 20% reduction in IOP was achieved by 67% of iStent inject patients and 50% of KDB patients (

Indexed as

glaucomaintraocular pressureiStentKahook Dual Blademicroinvasive surgery

Identifiers

PMID41149221
PMCPMC12564784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.