Evidence map›Paper›PMID 41148266›Full record

ArticleEuropean journal of trauma and emergency surgery : official publication of the European Trauma Society2025

K-wires as a valid alternative to dual and single headless cannulated compression screw fixation of chauffeur fractures: a biomechanical comparison.

Nicolas Catalin Ionut Ion, Bogdan-Axente Bocea, Ivan Zderic, Radu Sorin Fleaca, Mihai-Dan Roman, Cosmin-Ioan Mohor, R Geoff Richards, Mark Lenz, Boyko Gueorguiev, Ludmil Drenchev and 1 more

Abstract readComparative Study
In one paragraph

Article in European journal of trauma and emergency surgery : official publication of the European Trauma Society, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Nicolas Catalin Ionut IonAO Research Institute Davos, Davos, Switzerland. nicolascatalinionut.ion@ulbsibiu.ro.ORCID http://orcid.org/0009-0008-2143-1797
Bogdan-Axente BoceaAO Research Institute Davos, Davos, Switzerland.
Ivan ZdericAO Research Institute Davos, Davos, Switzerland.ORCID http://orcid.org/0000-0002-8155-4202
Radu Sorin FleacaFaculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.ORCID http://orcid.org/0000-0002-2444-9828
Mihai-Dan RomanFaculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.ORCID http://orcid.org/0000-0001-9856-8515
Cosmin-Ioan MohorFaculty of Medicine, Lucian Blaga University of Sibiu, Sibiu, Romania.ORCID http://orcid.org/0000-0002-9056-500X
R Geoff RichardsAO Research Institute Davos, Davos, Switzerland.ORCID http://orcid.org/0000-0002-7778-2480
Mark LenzDepartment of Trauma, Hand and Reconstructive Surgery and Orthopedics, University Hospital Jena, Jena, Germany.
Boyko GueorguievAO Research Institute Davos, Davos, Switzerland.ORCID http://orcid.org/0000-0001-9795-115X
Ludmil DrenchevBulgarian Academy of Sciences, Bulgarian Academy of Sciences, Institute of Metal Science "Acad. A. Balevski", Sofia, Bulgaria.ORCID http://orcid.org/0000-0003-3543-0636
Tatjana PastorAO Research Institute Davos, Davos, Switzerland.ORCID http://orcid.org/0000-0003-3440-5615

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeChauffeur fractures represent a distinctive subset of distal radius fractures and typically arise from a high-energy axial load or a direct blow to the volar aspect of the wrist. In cases of significant displacement, joint incongruity or functional impairment, surgical intervention becomes crucial. However, up to date there is no consensus about the best osteosynthesis treatment option. Therefore, the aim of this study was to investigate the biomechanical competence of Chauffeur fractures fixed with either one headless cannulated compression screw, two headless cannulated compression screws, or two Kirschner (K-) wires.

methodsEighteen right synthetic radii with a simulated Chauffeur fracture were assigned to three groups (n = 6) for fixation with either one headless cannulated compression screw (3.0 mm x 36 mm; Group 1), two K-wires (1.8 mm; Group 2), or two headless cannulated compression screws (2.2 mm x 30 mm and 2.2 mm x 36 mm; Group 3). The specimens underwent non-destructive biomechanical testing in neutral position, flexion, and extension, followed by progressively increasing cyclic loading to failure in neutral position with monitoring via motion tracking.

resultsInitial construct stiffness in flexion was significantly lower in Group 3 (202.4 ± 32.8 N/mm) versus both Group 1 (283.6 ± 31.3 N/mm) and Group 2 (275.3 ± 57.8 N/mm), p < 0.05. Cycles to failure and failure load in Group 2 (9214 ± 644; 510.7 ± 32.2 N) and Group 3 (8282 ± 973; 464.1 ± 48.7 N) were both significantly higher versus Group 1 (4678 ± 930; 283.9 ± 46.5 N), p < 0.05.

conclusionWhereas treatment of Chauffeur fractures with one cannulated compression headless screw is not recommended, using two K-wires is a valid alternative to the fixation of such fractures with two headless cannulated compression screws.

Indexed as

Bone ScrewsBone WiresFracture Fixation, InternalRadius FracturesBiomechanical PhenomenaHumansMaterials TestingChauffeurFractureK-wireRadiusScrew

Identifiers

PMID41148266
PMCPMC12568812

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.