ArticleCureus2025
Exploring Fully Navigated Minimally Invasive Spine Surgery-Transforaminal Lumbar Interbody Fusion (MISS-TLIF): An Institutional Analysis.
Article in Cureus, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Introduction Traditionally, percutaneous pedicle screw fixation has been guided using a C-arm. In recent years, 3D CT-based navigation systems have enabled improved visualization and navigated cage placement. However, the sequence of guide wire insertion, screw placement, and cage insertion continues to vary among surgeons, often depending on individual preference. Such variability can disrupt workflow efficiency and underutilize the full potential of navigation technology. A standardized, stepwise approach, initiated with a preoperative 3D O-arm spin and followed by sequential navigation at each step, can optimize workflow and minimize radiation exposure. Materials and methods We conducted a retrospective analysis of 44 patients who underwent fully navigated minimally invasive spine surgery-transforaminal lumbar interbody fusion (MISS-TLIF). After a 3D O-arm spin, a single 1-inch skin incision was made at the projected convergence points of the screws, and guide wires were inserted. On the decompression side, a fascial incision through the same skin opening allowed access via a medialized transmuscular TLIF approach. The procedure was performed using loupe magnification, a microscope, or an exoscope, depending on the case. Cage insertion was navigated, and pedicle screws were then placed over the pre-positioned guide wires. Final fixation was completed after confirming placement with a postoperative 3D spin. We analyzed patient demographics, pathology, surgical details, and radiological parameters. Outcomes included pedicle screw perforation, proximal facet joint violation (PFJV), local disc angle, posterior disc height, and pedicle screw convergence angle. Results Of the 44 patients included, 35 were female and nine were male. Navigated screw and cage placement was successfully achieved in all cases. The mean estimated blood loss (EBL) was 100 mL, and the average operative time was 124 ± 23.4 minutes. Visualization techniques included loupe magnification (n = 35), operating microscope (n = 9), and exoscope (n = 3). The Oswestry Disability Index demonstrated significant improvement at a mean follow-up of 38.7 ± 13.44 months. A total of 176 pedicle screws were placed, with 164 positioned accurately. PFJV occurred in 7% of screws (2% Grade 2 and 5% Grade 1 breaches). Radiological outcomes, including local disc angle and posterior disc height, were satisfactory and consistent with existing literature. Pedicle screw trajectory demonstrated improved medial convergence. Conclusions Fully navigated 3D CT-guided MISS-TLIF is a streamlined procedure that maximizes the capabilities of navigation technology while minimizing workflow disruptions. It overcomes the limitations of conventional C-arm-based techniques and variable surgeon-dependent workflows. This method enhances surgical precision, reduces complications such as pedicle screw breaches and facet joint violations, and facilitates improved screw convergence and cage placement accuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.