Evidence map›Paper›PMID 41144279›Full record

ArticleJournal of synchrotron radiation2025

Ultra-thin (<2 µm) silicon carbide free-standing membranes as beam position monitors for soft and tender X-ray beamlines.

E Medina, G Trovato, L Calcagno, S Kalbfleisch, M Birri, G Milluzzo, F Romano, E Sangregorio, S Moscato, F M Milian and 3 more

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

E MedinaINFN, Sezione di Torino, 10125 Torino, Italy.ORCID 0000-0003-3127-8577
G TrovatoSTLab srl, Via Anapo 53, 95126 Catania, Italy.ORCID 0009-0003-0164-537X
L CalcagnoDipartimento di Fisica e Astronomia Ettore Majorana, Università degli studi di Catania, Via Santa Sofia 64, 95123 Catania, Italy.
S KalbfleischMAX IV Laboratory, Lund University, PO Box 118, S-221 00 Lund, Sweden.
M BirriPaul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland.
G MilluzzoIstituto Nazionale di Fisica Nucleare - INFN, Sezione di Catania, Via S. Sofia 64, 95123 Catania, Italy.ORCID 0000-0001-5110-0659
F RomanoIstituto Nazionale di Fisica Nucleare - INFN, Sezione di Catania, Via S. Sofia 64, 95123 Catania, Italy.
E SangregorioSTLab srl, Via Anapo 53, 95126 Catania, Italy.ORCID 0000-0003-0044-5889
S MoscatoSTLab srl, Via Anapo 53, 95126 Catania, Italy.ORCID 0009-0003-8799-9805
F M MilianINFN, Sezione di Torino, 10125 Torino, Italy.ORCID 0000-0002-5588-1672
S GiordanengoINFN, Sezione di Torino, 10125 Torino, Italy.
A VignatiUniversità degli Studi di Torino, via P. Giuria 1, 10125 Torino, Italy.ORCID 0000-0001-8137-9080
M CamardaSTLab srl, Via Anapo 53, 95126 Catania, Italy.ORCID 0000-0003-2797-8802

Funding

Horizon 2020 Framework Programme 101007417Horizon 2020 Framework Programme 871130
6 · The paper itself

Abstract

Conventional beam intensity monitor technologies, such as `gold-meshes' and `diamond conductive thin films', currently applied to tender and soft X-ray beams, encounter numerous application challenges, including diffraction effects, low signal strength, non-uniform transparency, and lack of position information. This study explores the potential of very thin (<2 µm) silicon carbide free-standing membranes, as in-line, minimally interfering beam intensity and position monitors, with high-lateral resolution, for soft and tender X-ray beamlines. Initial experimental assessments were conducted at the NanoMAX beamline at MAX IV to analyze the performance of such very thin devices in monitoring tightly focused (<1 µm FWHM) beams. The tests revealed that employing four-quadrant sensor layouts on such thin sensors resulted in significant charge collection losses in the regions between the quadrants and, under high electric field conditions, in charge multiplication effects (avalanche effects). Through Sentaurus TCAD theoretical simulations, the limitations of the four-quadrant design for such applications and the potential of an alternative technology (resistive X-ray beam postion monitor) were clarified.

Indexed as

beamline instrumentationbeam position monitorsdetector simulationsradiation detectorsilicon carbideX-rays

Identifiers

PMID41144279
PMCPMC12591062

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.