ArticleJournal of hand and microsurgery2025
The shield multicentre collaborative: A study of hand surgeons' intraoperative radiation exposure and techniques to limit dosing.
Article in Journal of hand and microsurgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: Fluoroscopic radiographic imaging is indispensable in modern hand surgery. Challenges in positioning patient digits during complex hand injury assessments can result in direct radiation exposure to operating staff. The adverse health risks associated with radiation exposure, including malignancy, are well documented and demand clear risk reduction strategies. The EURATOM 2013/59 directive provides guidance on reducing occupational exposure under the 'as low as reasonably achievable' (ALARA) principle. This study aims to assess the prevalence of non-patient (surgeon) anatomy in intra-operative radiographs and outline prevention strategies to optimise radiation safety practices for hand surgeons. Methods: A national multi-centre audit of direct occupational hand surgeon radiation exposure was performed. Intra-operative radiographic images obtained during hand surgery cases across six plastic and reconstructive surgery centres were retrospectively reviewed. The primary outcome was the presence of non-patient (surgeon) anatomy in intra-operative radiographic images. Secondary outcomes include timing of surgery (working hours vs. out-of-hours), procedure type and surgeon seniority (consultant vs. trainee). Results: A total of 852 hand trauma procedures performed across the six national centres across a three-year period were included. Non-patient digits were present in intra-operative radiographs in 51.7 % of cases (range, 22.3-78.3 %). The most common procedure was fracture reduction and k-wire fixation (n = 515, 60.4 %). There was significant variance between the surgical units in the rate of non-patient anatomy captured, indicating inter-hospital differences in radiation safety practice adherence. Twenty-two percent of procedures were performed out-of-hours. There was no significant relationship between radiation exposure and procedure timing or surgeon seniority. Conclusions: Hand surgeons are frequently exposed to excess intra-operative radiation. Radiation safety training, strict adherence to intra-operative radiation safety protocol, formal radiation safety education, and use of innovative surgical equipment, may help reduce the rates of radiation exposure in hand surgery. Type of study: Differential diagnosis/symptom prevalence study. Level of evidence: 2c.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials