Evidence map›Paper›PMID 41141227›Full record

ArticlePhysics and imaging in radiation oncology2025

Surface-guided breathing signal integration in breathing-adapted intelligent 4D computed tomography: prototype implementation and comparison with an infrared marker-based system.

Niklas A Lackner, Torsten Moser, Julian Young, Jannis Dickmann, Volker That, Christian Hofmann, Andre Karius, Mushawar Ahmad, Oliver J Ott, Florian Putz and 3 more

Abstract read
In one paragraph

Article in Physics and imaging in radiation oncology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Niklas A LacknerDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Torsten MoserVision RT LTD, London, United Kingdom.
Julian YoungVision RT LTD, London, United Kingdom.
Jannis DickmannSiemens Healthineers AG, Forchheim, Germany.
Volker ThatSiemens Healthineers AG, Forchheim, Germany.
Christian HofmannSiemens Healthineers AG, Forchheim, Germany.
Andre KariusDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Mushawar AhmadDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Oliver J OttDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Florian PutzDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Rainer FietkauDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Christoph BertDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.
Juliane SzkitsakDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstraße 27, 91054 Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose: Breathing-adapted intelligent four-dimensional computed tomography (i4DCT) reduces motion artifacts during irregular breathing using real-time surrogate signal analysis to control X-ray timing. Current implementations rely on infrared (IR) markers or pressure belts. Surface-guided radiation therapy (SGRT), a widely used markerless technique in radiotherapy, has not been evaluated for direct i4DCT integration. This study tested SGRT for i4DCT acquisition in a phantom setup and benchmarked it against an infrared marker-based system. Materials and methods: Phantom measurements with clinically relevant regular and irregular breathing signals were performed on a prototype CT scanner with direct SGRT control. To improve SGRT-based surrogate accuracy, a table motion correction profile was empirically modeled, and a vendor-specific prediction algorithm was implemented. Surrogate signal accuracy, latency, and motion reconstruction accuracy were compared between SGRT and an established IR system using amplitude- and phase-based reconstructions. Results: SGRT exhibited an absolute latency of ∼ 63  ms, compared to ∼ 23  ms for the IR system. Across regular and irregular breathing signals, SGRT breathing signals showed Root Mean Square Error (RMSE) values up to ∼ 1.5  mm, while correlation with the ideal signal remained high (r = 1). Tumor center-of-mass deviations in amplitude-based reconstructions reached 1.5  mm without prediction at 20 breaths-per-minute and 15  mm amplitude, but reduced to < 0.5  mm with 50  ms prediction. Both amplitude- and phase-based reconstructions showed improved agreement with ideal motion when prediction was applied, with phase-based reconstructions yielding better accuracy. Conclusions: These findings support SGRT as a clinically viable non-contact alternative to IR tracking in i4DCT, especially when combined with motion correction and predictive modeling.