Evidence map›Paper›PMID 41140348›Full record

ArticleAmerican journal of ophthalmology case reports2025

Smaller spot sizes show bitemporal visual field defects missed by standard Humphrey perimetry.

Nicole Y Tsai, Jonathan C Horton

Abstract readCase Reports
In one paragraph

Article in American journal of ophthalmology case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Nicole Y TsaiWilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
Jonathan C HortonDepartment of Ophthalmology, University of California, San Francisco, CA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To compare the sensitivity of Humphrey visual field (HVF) tests using different stimulus spot sizes for the detection of early visual field defects in a patient with known chiasmal compression. Observations: A 21-year-old man with a suprasellar tumor compressing the optic chiasm had multiple normal 24-2 HVF tests using a stimulus size III test spot over 5 years. Subsequent ganglion cell complex (GCC) analysis on optical coherence tomography (OCT) showed ganglion cell layer + inner plexiform layer (GCL + IPL) thinning in the macula. Therefore, HVF testing was performed using smaller test spots. Size I and II spots both revealed a superior temporal field defect in each eye that was missed by the standard size III spot. Conclusions and importance: These findings demonstrate that HVF testing using stimulus size I or II spots can reveal a visual field defect that was missed when using a standard size III spot. We therefore recommend routinely performing HVF testing in patients with known chiasmal compression with a stimulus size I or II spot, when testing with a stimulus size III spot is negative.

Indexed as

Chiasmal compressionPerimetryRicco's areaStimulus sizeVisual fields

Identifiers

PMID41140348
PMCPMC12546789

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.