Evidence map›Paper›PMID 41139871›Full record

ArticleJournal of applied clinical medical physics2025

Impact of eFOV CT distortion on surface-guided radiotherapy registration: Phantom-based analysis.

Wooseok Kim, Hyunsoo Jang, Eng Chan Kim, Jonggeun Baek, Byungyong Kim

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wooseok KimDepartment of Radiation Oncology, Pohang St. Mary's Hospital, Pohang-si, Gyeongsangbuk-do, Republic of Korea.
Hyunsoo JangDepartment of Radiation Oncology, Pohang St. Mary's Hospital, Pohang-si, Gyeongsangbuk-do, Republic of Korea.
Eng Chan KimDepartment of Physics, Yeungnam University, Gyeongsan-si, Gyeongsangbuk-do, Republic of Korea.
Jonggeun BaekDepartment of Radiation Oncology, Dongguk University Gyeongju Hospital, Gyeongju-si, Gyeongsangbuk-do, Republic of Korea.
Byungyong KimDepartment of Radiation Oncology, Keimyung University Dongsan Hospital, Dalseo-gu, Daegu, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluated the impact of extended field-of-view (eFOV) CT distortion on the alignment accuracy of surface-guided radiation therapy (SGRT) using CT-based reference surfaces, and examined the influence of beam center location.

methodsAn anthropomorphic phantom, segmented into chest, abdomen, and pelvis, was scanned at the center position (sFOV) and at four off-center positions. The center corresponds to the CT bore isocenter, while the off-center positions were obtained by placing the phantom boundary 315 mm or 390 mm to the left or right of the CT isocenter to simulate eFOV conditions. Geometric distortion was assessed by measuring external body contour volume. Treatment plans were generated with beam centers at the isocenter and at off-center positions of 8 cm left and right. SGRT registration accuracy was evaluated from SGRT alignment error and cone-beam CT (CBCT) alignment error differences using axis-specific mean absolute errors (MAEs) and overall translational and rotational root mean square errors (RMSEs).

resultsDistortion was most pronounced in the chest when the phantom boundary was 390 mm right of the isocenter, with a 12.55% volume reduction. In contrast, abdomen and pelvis volume changes were within 1% across all positions. At the isocenter, MAEs increased at 390 mm off-center positions, with chest showing lateral/vertical errors and abdomen exhibiting longitudinal/rotational deviations. When the beam center was 8 cm lateral and adjacent to a distorted region, errors increased, while contralateral placement showed errors comparable to the isocenter. Maximum RMSEs of 10.98 mm (translation) and 5.88° (rotation) occurred in the abdomen when beam centers overlapped distorted regions, exceeding typical clinical thresholds (5 mm, 2°). The pelvis showed relatively stable alignment with RMSEs within 2.5 mm and 1.5°.

conclusionThis phantom study demonstrated that eFOV reconstruction can compromise SGRT alignment accuracy, particularly when beam centers are located near distorted regions. Alignment remained within clinically acceptable limits when reference points were sufficiently distant from distortion. These findings provide important baseline data under controlled conditions, and clinical validation with patient cohorts is warranted to confirm their generalizability.

Indexed as

Cone-Beam Computed TomographyImage Processing, Computer-AssistedNeoplasmsPhantoms, ImagingRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansOrgans at RiskPelvisRadiotherapy DosageRadiotherapy, Intensity-Modulatedextended field‐of‐viewimage registrationreference surfacesurface‐guided radiation therapy

Identifiers

PMID41139871
PMCPMC12554787

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.