Evidence map›Paper›PMID 41136030›Full record

ArticleJACC. Case reports2025

30-Day Outcomes of a Controlled-Bending Delivery System for TAVR in Severe Aortic Stenosis.

Yang Chen, Zhongyu Wang, Baihua Sun, Guoliang Chen, Pinghai Zhang, Jicheng Xi, Yongjian Wu

Abstract read
In one paragraph

Article in JACC. Case reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yang ChenCoronary Heart Disease Center, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China; Department of Cardiology, Peking University People's Hospital, Beijing, China.
Zhongyu WangDepartment of Medicine, Qingdao University, Qingdao, Shandong, China.
Baihua SunDepartment of Radiology, Linyi People's Hospital, Linyi, Shandong, China.
Guoliang ChenDepartment of Cardiac Surgery, Shanxi Cardiovascular Hospital, Taiyuan, China.
Pinghai ZhangShanghai MicroPort CardioFlow Medtech Co Ltd, Shanghai, China.
Jicheng XiDepartment of Cardiac Surgery, Shanxi Cardiovascular Hospital, Taiyuan, China. Electronic address: 3452893059@qq.com.
Yongjian WuCoronary Heart Disease Center, National Center for Cardiovascular Diseases and Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: wuyongjian@fuwai.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This report presents the first-in-human experience with a 3-dimensional controlled-bending, fully retrievable delivery system for transfemoral transcatheter aortic valve replacement in severe aortic stenosis with anatomical challenge. In a prospective single-center series (September-December 2023) of 6 high-risk patients (mean age: 68.0 ± 3.9 years, 84% bicuspid valve, all with complex features such as horizontal heart or dilated ascending aorta), the device success rate was 100%, implantation was coaxial (implantation depth difference: 2.32 ± 1.53 mm), and postprocedural paravalvular leak was none to trivial. Hemodynamics improved substantially (gradient decreased from 75.5 ± 12.3 to 7.9 ± 2.1 mm Hg, effective orifice area increased from 0.61 ± 0.15 to 2.26 ± 0.34 cm

Indexed as

aortic valvebicuspid aortic valvetreatmentvalve replacement

Identifiers

PMID41136030
PMCPMC12789823

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.